Setup and Measurement Procedures
4.1.2
Setup and Measurement Process
The Profiler 2 performs measurements according to the following flow.
Settings are also performed for each of these items.
Laser control input
Trigger signal
Output is
stopped
during
settings.
Camera imaging
Camera settings
Profile
Profile settings
Area measurement
Area settings
Area calculation
Calculation settings
Result judgment and output
Output settings
Out 1
Out 2
Out 3
Analog
Judgment output (control output)
Analog output
1. Trigger
• Images are captured when the set conditions are met.
2. Camera
• An image is captured based to the settings.
3. Profile acquisition
• The profile (the sectional profile made by the reflected laser light)
is acquired from the image.
4. Area measurement
• The specified position within the profile is measured.
5. Area calculation
• If necessary, the measured result of the area is calculated. e. g. Area
1 – Area 2 = Calc 1)
6. Result judgment and output
• The measured result is compared against the threshold, and then the
judgment result is output.
Tips: •
With the Profiler 2, you can save settings related to measurements
in “banks.” Up to eight banks can be saved.
Reference: For details on banks, see “7.9.1 Banks.”