Master module
OA-EDGE T
5916332 FEB 2013
NM-0001-5
Model
Profile color
Mounting height
Detection area
Detection method
Depth angle
adjustment
Power supply *
Power consumption
LED indicator
Test input
Safety / Test output 1
Safety / Test output 2
: OA-EDGE T
: Silver / Black
: 1.5 (4'11") to 3.0m (9'10")
: See
DETECTION AREA
: Triangulation
: 0° to +25°
: 12 to 24VAC ±10% (50 / 60 Hz)
12 to 30VDC ±10%
: < 1.3W (< 2VA at AC) at Min. configuration
< 3.5W (< 4.5VA at AC) at Max. configuration
: See chart below
: Opto coupler 10 to 30VDC
Current / 6mA Max.
Output hold time
Response time
Operating temperature
Operating humidity
IP rate
Performance level
: Approx. 0.5 sec.
: <75msec.
: -20 to +55°C (-4 to 131°F)
: <80%
: IP54
: d (EN ISO13849-1 : 2008)
The specifications herein are subject to change without prior notice due to improvements.
NOTE
WARNING
CAUTION
NOTE
Disregard of warning may cause improper operation causing death or serious injury of
a person.
Special attention is required to the section of this symbol.
Setting to meet the requirements by EN16005.
Disregard of caution may cause improper operation causing injury of a person or damage to
objects.
NOTE
LED indicator
The following conditions are not suitable for sensor installation :
- Fog or exhaust emission around the door.
- Wet floor.
- Moving objects or objects that emit light near the detection area.
- Highly reflecting floor or highly reflecting objects around the door.
NOTE
Solid Green
Slow Green blinking
Twice Green blinking
Blinking Red
Status
Stand-by
Opening side detection (output 1)
Closing side detection (output 2)
Incomplete Initialization
Learning
Incomplete learning
Saturation
Sensor failure
Sensor module
indicator
Communication error
Solid Red
Solid Orange
Red & Green blinking
Yellow & Red blinking
Slow Red blinking
Fast Red blinking
Twice Orange blinking
Blinking Yellow
Profile
Front cover
Mounting clip
LED module
Spacer
Endcap
Power supply connector
Communication connector
LED indicator
Dipswitch A
Dipswitch B
Function switch
Angle adjustment screw
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
NOTE
Make sure to fix the sensor modules firmly by the mounting clips.
: Form C relay
Voltage / 42VDC
Current / 0.3A Max (Resistance load)
Output : see
INSTALLATION
chapter
3. Wiring
* : The sensor has to be connected to a
door system is equipped with a SELV circuit.
The overcurrent protection of power supply
cable has to be less than 2A.
(7)
(8)
(10)
(11)
(12) (8)
(7)
The lens that is marked "Tx" must be positioned onto the corresponding door edge.
Refer to
DETECTION AREA
for the sensor module position. The sensor module can be inserted
in reverse as shown below. To do this,detach the mounting clip and rotate the sensor module by 180°
and reattach the mounting clips.
unit : mm (inch)
It is required to check the operation manual if this symbol is shown on the product.
Install the sensor at 1.8m (5'11")
to 2.5m (8'2").
WARNING
Do not wash, disassemble, rebuild or repair the sensor otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a
person.The meanings of the symbols are as follows.Please study the following first and then read the contents of this
operation manual.
1. This sensor is a non-contact switch intended for door mounting and to use on automatic swing doors.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the sensor is installed.
6. Before leaving the installation site make sure that the sensor is operating properly and instruct the building
owner/operator on proper operation of the door and the sensor.
7. The sensor settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
ENGLISH
ON
ON
Tx
Slave module
(8)
(11)
(8)
1
2
3
Min. configuration
: 1 master 1 LED module
Max. configuration
: 4 sensor m2 LED modules
(1)
(2)
(3)
(3)
(4)
(6)
(6)
(5)
(9)
(9)
Sensor module
MANUFACTURER'S STATEMENT
MANUFACTURER'S STATEMENT
SPECIFICATION
OUTER DIMENSIONS AND PART NAMES
INSTALLATION
2
Inserting the sensor module
1
Mounting the profile
Noise level
: <70dBA
(13)
(13)
ON
Tx
ON
ON
Tx
ON
ON
Tx
COMPLIED STANDARDS
Notified Body : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany
EC-type examination certificate No. 44 205 13 417493-002
EN16005
LED module indicator
ON : Solid Red
Original instructions
Category
: 2 (EN ISO13849-1 : 2008)
- Grating floor.
NOTE
1. Take the sensor modules out of the profile.
2. If the profile is longer than the door width, cut the profile. Make sure not to scratch the front cover.
3. Affix the profile on the intended mounting position leaving more than 20mm (13/16") from door edge to
attach the endcap.
4. If necessary, drill two mounting holes of ø3.4mm (ø1/8”) and fix the profile.
5. When mounting a sensor on each side of the door, it is necessary to drill a wiring hole of ø12mm (ø1/2”) to
connect the sensor modules. (See chapter
3. Wiring
)
Make sure there is some space between the mounting clips and the mounting screws.
Min. 20mm
(13/16")
1
2
Make sure not to scratch the profile when making a hole.
Safety / Test output 1
OFF : Solid Green
ON : Solid Orange
Safety / Test output 2
OFF : Solid Green
The color depends on
the state of the output.
50.7 (2")
44.3 (1 3/4")
X =Minimum 340mm (13 3/8")
Black screw
(small)
Silver screw
Recommended installation position
Mounting height
Detection area width
Door width
W
h
d1
=
=
=
=
=
=
Distance from the leading edge to the sensor module
unit : mm (inch)
h
d1
d3
W
900 (2'12")
1900
(6'3")
2000
(6'7")
2100
(6'11")
2200
(7'3")
2300
(7'7")
2400
(7'11")
2500
(8'2")
760
(2'6")
790
(2'7")
825
(2'9")
870
(2'10")
895
(2'11")
920
(3')
950
(3'1")
175
(6 7/8")
160
(6 3/8")
145
(5 6/8")
125
(5")
115
(4 1/2")
110
(4 1/2")
110
(4 3/8")
d2
n
2
2
2
2
2
2
2
d3
1100 (3'7")
375
(14 3/4")
355
(14")
345
(13 5/8")
320
(12 5/8")
315
(12 3/8")
310
(12 2/8)
300
(11 6/8")
n
2
2
2
2
2
2
2
d3
1200 (3'11")
420
(16 4/8")
415
(16 2/8")
410
(16 1/8")
400
(15 3/4")
n
2
2
2
2
2
2
2
Number of sensor modules
Distance between sensor modules
d3
d2
n
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
70
(2 3/4")
475
(18 5/8")
460
(18 1/8")
445
(17 1/2")
Test conditions required by EN 16005 Detection object : EN 16005 CA reference body
The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
NOTE
NOTE
DETECTION AREA
Detection area at 2200mm (7' 2 5/8") : Depth 140 (5 1/2") x Width 870 (2'10")
Emitting area at 2200mm (7' 2 5/8") : Depth 140 (5 1/2") X Width 440 (1' 5 1/2")
Leading edge
h
EN 16005 CA
reference body
d2
d3
d1
W
For instaltion heigths <1900mm the installation of an extra module will be mandatory in order to comply
with the regulations.
EN16005
EN 16005:2012
EN 12978:2003 +A1:2009
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
EN ISO 13849-1:2008
EN ISO 13849-2:2008
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3