Dipswitch A

Dipswitch B

NOTE

Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield otherwise it may 
cause electric shock or breakdown of the sensor.

WARNING

Danger of electric shock

ON

To the power supply
connector of 
the master module

ON

NOTE

Only correctly initialising the sensor ensures 
the correct functioning of the dipswitches
(see chapter 

2. Function switch

)

Set Dipswitch A3 to ON when the sensor operates by itself (ghosting).

NOTE

When Dipswitch A3 is set to ON ,the actual detection area may 
become smaller than Immunity off.

A2

Setting1

OFF

A2

Setting2

ON

A3

Immunity on

ON

A3

Immunity off

OFF

1-3.Setting the immunity

1-2.Setting the frequency 

When installing the sensors on a double swing door make sure that the frequency on
each sensor is set differently.

Each module has three communication connectors.
Use the most convenient connector for the
installation site.

Maximum of three sensor modules can be connected to one master module.

}

1.White 

2.Brown 

3.Green

4.Yellow

5.Grey

6.Pink

7.Blue

8.Red

9.Black

10.Violet

Power supply
 

12 to 24VAC ±10% , 12 to 30VDC ±10% 

Safety / Test output 2
  

Form C relay 

  Reverse impulse (Closing side) 

}

Test input

  Opto coupler / Voltage: 10 to 30VDC

(+) 

(-)

COM.

N.C. 

N.O.

COM. 

N.C.

N.O.

(+)

(-)

}

}

Safety / Test output 1
  

Form C relay 

  Stop impulse (Opening side) 

NOTE

The value is a reference for 
a mounting height of 1.8 to 2.5m 
( 5' 11" to  8' 2" ).

Non detection 
zone

Side view

B1

Non detection zone (B)

B2
B3
B4

Mounting side (Output select)

Area width
Self monitoring

A1

A4
A5
A6
A7
A8

Non detection zone (A)
Frequency
Immunity

Test input
Test input delay

For future use

A3

A2

Non detection zone

35cm

(13 3/4")

25cm

(9 13/16")

45cm

(17 11/16")

15cm

(5 7/8")

ON : "+10cm"

OFF : "+0cm"

Dipswitch A1

OFF : "15cm"

OFF : "15cm"

ON : "+10cm"

OFF : "+0cm"

ON : "35cm"

ON : "35cm"

Dipswitch B1

INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS 

1. Always keep the front cover clean. If dirty, wipe it with a damp cloth. (Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When LED indicator blinks Fast Red without any object in the detection area, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the front cover.

WARNING

1. After applying power, wait 10 seconds then walk test detection area to ensure proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)

NOTE

ADJUSTMENTS

INSTALLATION

Connect the communication cable of the LED module to the master or slave module.
Attach the spacer on the endcap side. Insert the LED module to the profile as shown below.
The LED module can be inserted to both side of the profile.

4

Inserting LED module

After 

ADJUSTMENTS 

are completed, place the front cover and endcaps.

5

Placing the front cover

Each Master module is equipped with Dipswitch A and Dipswitch B and each Slave module is equipped with 
only Dipswitch B. Only dipswitch A of the master module connected to the door controler is applicable and 
will reflect the settings to all connected master and slave units automatically.

1

Dipswitch settings

The non detection zone is the height measured from the floor up to the position where the sensor starts to detect.
The zone can be set by a combination with Dipswitch A1 & B1. 
[Non detection zone value] = [Dipswitch A1 value] + [Dipswitch B1 value]

1-1.Setting the non detection zone

NOTE

B2

4spots

OFF

2-1.Initialization

Do not enter the detection area when the sensor is performing a learning cycle.
When the initialization and the learning cycle is completed, the sensor will be in stand-by mode and
the LED will show solid green.

After the adjustment, check the detection area.

2-2.Learning

By selecting the sensor position the outputs & LED indicator will 
function as shown below :

1-8.Setting the mounting side
       (output select)

1-6.Setting the area width

2

Function switch

3

Area depth angle adjustment

When the door remains open or closed, please refer to the 

TROUBLESHOOTING

 section. If the door still remains open or 

closed, set dipswitch B3 to "Disable"

Set Dipswitch B3 to "Enable".

.

1-7.Setting the self monitoring

B3

OFF

B3

ON

Disable

  Enable

B2

2spots

ON

The angle of each sensor module must be adjusted so that the door stops 
before it comes into contact with an obstacle. After area angle adjustments, 
start the learning as described in 

chapter 2.Function switch

.

 Adjustable angle : 0° to +25°

Angle adjustment screw

OFF :"Opening side
         (output 1)"

Dipswitch B4

Output

Safety / Test output1

(stop impulse)

Solid Red

(detection)

ON :"Closing side
         (output 2)"

Safety / Test output2

(reverse impulse)

Solid Orange

(detection)

LED

indicator 

NOTE

Check the operation according to the chart below.

Outside of

detection area

COM.

N.C.

N.O.

CHECKING

COM.

N.C.

N.O.

The door movement might become unstable right after the learning. The movement becomes
stabilized after several openings and closings.
Always walk-test the detection area to ensure the proper operation.

Entry into 

opening side 

detection area

Entry into 

closing side 

detection area

Entry

Power OFF

Status

-

Detection active

Detection active

Stand-by

LED indicator

None

Solid Red

Solid Orange

Solid Green

Safety / Test output1

(Stop impulse)

Safety / Test output2

(Reverse impulse)

COM.

N.C.

N.O.

COM.

N.C.

N.O.

COM.

N.C.

N.O.

COM.

N.C.

N.O.

TROUBLESHOOTING

Problem

Possible cause

Possible countermeasures

 The sensor has no function Wrong power supply voltage

Set to the stated voltage.

Wrong wiring or connection failure

Check the wiring and connectors.

Incomplete initialization
 (Red & Green blinking)

Initialization has not been conducted.

Push the function switch for more than 2 sec. for 
initialization.

Dipswitch setting is changed.

Initialization is not finished
(Red & Green blinking 
 continuous)

More than 2 master modules are connected 
with power supply wire.

Connect the power supply cable to only one 
master module.

Incomplete learning
(Yellow & Red blinking)

Initialization has not been conducted.

Push the function switch for less than 2 sec. for 
learning.

Learning does not start
(Twice Orange blinking)

Check the communication wires or change wires.

Communication error

Sensor operates by itself.
(Ghosting) or 
learning is not finished.
(Yellow & Red blinking 
 continuous)

The modules are affecting each other.

Change the module positions or adjust angles 
or adjust the area width (Dipswitch B2).

Same frequency setting on double swing 
door application.

Set the different frequencies. (Dipswitch A2)

Objects that move or emit light in the 
detection area. (Ex.Plant, illumination, etc.)

Remove the objects.

The floor pattern is not plain or ‚
the door movement is irregular.

Set the immunity (Dipswitch A3) to "ON".
Extend the non detection zone.

Signal saturation.

Sensor operates by itself. 
(Ghosting)

Waterdrops on the front cover

Install in a place keeping the waterdrops off.

The module angle is changed.

Check the module angles.

The sensor functions 
without the front cover 
but not with it.

The front cover is dirty.

Wipe the front cover with a damp cloth.
(Do not use any cleaner or solvent.)

The front cover is scratched

Replace ‚the front cover.

Sensor operation is not 
linked to door movement.

Connection error or 
wrong mounting side setting.

Check the wiring or mounting side setting.
(Dipswitch B4)

Door remains open 
or closed without any 
object in the detection 
area.

Presence timer set to infinity and sudden 
change in the detection area.

Push the function switch for less than 2 sec. for
learning. Or change presence timer setting. 
(Dipswitch A4)

Signal saturation. (Slow Red blinking)

The front cover on inner or outer side is dirty. Wipe the front cover with a damp cloth.

(Do not use any cleaner or solvent.)

Check the communication wires.

Communication error. (Twice Orange blinking)

The sensor is affected by the floor color.

Push the function switch for less than 2 sec. for
learning. Or extend the non detection zone.

Sensor failure. (Fast Red blinking)

Contact your installer or service engineer.

Change the module positions or  adjust angles 
or adjust the area width (Dipswitch B2).

Only the master module is equipped with a function switch. The function switch of the master module that is 
connected to the door controller is only applicable to reflect settings to all sensor modules connected.

After a dipswitch setting change or when the power is supplied for the first time, the LED blinks red & green.
Push the function switch for more than 2 sec. and then the LED indicator on the master unit will switch off.
The LED indicator will start to blink green to indicate the number of connected sensor modules.
The LED indicator will start to blink yellow and red and the initialization is completed. The LED is now indicating 
that you have to proceed a learning cycle.

Push the function switch for less than 2 sec. and then the LED indicator will start to blink yellow. The sensor will 
learn the non detection zone.

To Master / Slave 
module

For LED status see 

SPECIFICATION

NOTE

Make sure to use the function switch when the door is in the fully closed position.

NOTE

NOTE

When a test input is not required, set the dipswitch A7 to OFF.

Slave module 

Slave module

Slave module

Door
controller

Power supply cable

Communication cable

Door

LED 

module

LED 

module

Master module *

*  When more then 1 master module is installed on the door leaf, make sure that only one power 
   supply cable is connected to the operator otherwise initialization can not be completed. 
   All other master units will automatically function as a slave unit.     

Wire the cable to the door controller as shown below.

3

Wiring

NOTE

1-4.Setting the presence timer

If an object remains in the detection area longer than the setting, LED 
indicator may blink fast Red. In this case, it is not Sensor failure.
After an object is removed, LED indicator will show solid Green.

NOTE

A4

60sec.

OFF

A4

ON

Presence timer

The presence timer can be set by Dipswitch A4. 

Set dipswitch B2 to "2 spots" when a narrow 
detection area is required.

Test input

(from door controller)

Safety / test output

(to door controller)

High

Test input

Detection

* Test input delay time (=t2)

A7

Low

A7

N.O.

N.C.

Set dipswitches A7 & A8 according to the instructions from the door controller.

t1(>t2)

t2

t2

1-5.Setting the test input and test input delay time

open

close
open

close

A8

A8

20msec.

10msec.

OFF

ON

* The test input delay time is the time period between the test input and Safety / Test output.

Test input and Safety / Test output timing chart

OFF

ON

EN16005

EN16005