15. Problem:
The unit does not turn on – the Power LED on the front panel does not light up and the unit cannot be accessed
by any external devices.
Solutions:
Check the power connections and cables.
Contact your vendor for assistance.
Note: Do not open the Video Gateway. It contains no user-serviceable parts.
16. Problem:
The unit disconnects from and reconnects to SVMultiClient every few minutes.
Solutions:
Check that the external LAN connection is connected to the
Ethernet Out
connector on the rear of the
unit.
Contact your vendor for assistance.
17. Problem:
The internal speaker on the HVG400 is enabled but sound that is transmitted from a client device is not audible.
Solution:
Ensure that the
Mute
button on the rear of the unit is turned off.
Configuring General System Settings
, page 21 (in particular, see the note about the
Speaker
field on page 86)
18. Problem:
WiFi is enabled in the
WiFi
screen, but the Video Gateway does not connect to any of the access points; all the
configured access points are "Not in Range."
Solutions:
Ensure that the access points are running and are in range of the Video Gateway unit.
Ensure that the WiFi antenna is securely attached to the
WiFi
connector on the rear panel of the unit.
Ensure that the Video Gateway is not configured to function as a WiFi access point; if it is configured to
function as an access point, it cannot also connect to other access points.