The Sapling Company, Inc.
670 Louis Drive
Warminster, PA 18974
USA
P. (+1) 215.322.6063
F. (+1) 215.322.8498
www.sapling-inc.com
10) Connect all power and communication cables
to the appropriate ports on the circuit board. You
should have already configured the clock using the
instructions provided earlier. If not, please take the
clock down and do so now. For information on
wiring, refer to the sections of this manual labeled
Inputs and Outputs.
12) Use the Phillips screwdriver to close the wiring
panel.
11) Screw the seal nuts back onto the wiring panel.
9) Pass all power and communication cables
through the seal nut, followed by the gasket on
the wiring panel.
Wall Mount Installation
3.3V, 100MA
3.3V, 100MA
Timer RX
Temp RX
Common
Timer TX
Temp TX
Not Used
Not Used
Input B+
Output A-
Output B+
Rly1 NO .5A 120vac/24vdc
Rly2 NO .5A 120vac/24vdc
User 1 Input
User 2 Input
User 3 Input
User 4 Input
Common
5V, 40MA
9 -12V, 40MA
Dukane Pulse
Dukane Reset
24Vac Sync
120Vac Sync
AC/DC Com
AUX
5V Dry Cont
(-) Neutral
(+) Line
Earth
1
1
1
1
1
J4
J5
J7
J10
J11
J9
RS485
Common
Input A-
5
5
4
8
10
24 VAC/DC
110/220 VAC
Power over Ethernet
Locally Powered
If you are installing an elapsed timer, go to “Elapsed Timer Control Panel Installation - Optional Accessory”
If you are installing a temperature sensor, go to “Temperature Sensor Installation - Optional Accessory”