Control
C - 9
■
List of Remote Control Warnings (when a water heat exchanger unit is connected)
3. List of Warnings
Detection item
Remote control reception failure
Remote control transmission failure
Defective reception by water heat exchanger unit from remote control
Defective reception by water heat exchanger unit from outdoor unit
Defective transmission by water heat exchanger unit to outdoor unit
Defective reception by outdoor unit from water heat exchanger unit.
Defective transmission from outdoor unit to water heat exchanger unit.
Defective setting
Duplicate setting of the water heat exchanger unit address
Defective transmission from water heat exchanger unit to remote control
Outdoor controller board abnormality
Outdoor controller board sensor abnormality
Abnormal transmission within a unit
Non-conformance of indoor and outdoor unit types
Defective setting of
the number of water
heat exchangers at
the outdoor unit
Too few units
Too many units
Duplication of system (outdoor unit) address settings (cables linking)
Outdoor unit capacity not set
Defective setting of water heat exchanger unit
Parallel address duplicated
Defective gas type setting
Sensor system
abnormality on the
water heat
exchanger side
Water heat exchanger unit refrigerant inlet temperature sensor abnormality
Water heat exchanger unit freeze prevention sensor abnormality
Water heat exchanger outlet temperature sensor abnormality
Cold and hot water inlet sensor abnormality
Cold and hot water outlet sensor abnormality
Compressor outlet temperature sensor abnormality
Sensor system
abnormality on the
outdoor unit side
Outdoor heat exchanger inlet temperature sensor abnormality
Outdoor heat exchanger outlet temperature sensor abnormality
External air temperature sensor abnormality
Compressor inlet temperature sensor abnormality
Cooling water temperature sensor abnormality
Compressor inlet/outlet pressure sensor abnormality
Exhaust gas temperature senor abnormality
Clutch coil temperature sensor abnormality
Water heat exchanger unit nonvolatile memory (EEPROM) abnormality
Clock function (RTC) abnormality
Outdoor nonvolatile memory (EEPROM) abnormality
Remote control detects
an abnormal signal from
an indoor unit
E01
E02
E03
E04
E05
E06
E07
E08
E13
E15
E16
E21
E22
E31
L02
L04
L10
L16
L19
L21
F01
F02
F03
F10
F11
F04
F06
F07
F08
F12
F13
F16
F18
F20
F29
F30
F31
Abnormal serial transmission, incorrect setting
Incorrect setting or no setting
Sensor abnormality
Device
checked
Remote
control
Water heat
exchanger
unit
Water heat
exchanger
unit
Water heat
exchanger
unit
Water heat
exchanger
unit
Water heat
exchanger unit
Outdoor unit/
water heat
exchanger unit
Outdoor
unit
Outdoor
unit
Outdoor
unit
Outdoor
unit
Outdoor
unit
Warning
display
Remote control
switch display
Water heat exchanger
unit board display
"Abnormal" lit
"Abnormal" lit
"Abnormal" lit
"Abnormal" lit
LE8 Flashing
LE23 Lit
LE8 Flashing
LE23 Lit
LE11 Flashing
LE23 Lit
LE9 Flashing
LE23 Lit
LE23 Lit
LE23 Lit
LE23 Lit
LE23 Lit
Summary of Contents for SGP-E120J2GU2
Page 49: ...Design D 5 2 Operating temperature ranges for heating and cooling Cooling Heating ...
Page 87: ...Design D 43 8 Salt resistant specification ...
Page 109: ...Construction E 22 4 Outdoor unit installation and construction ...
Page 110: ...Construction E 23 4 Outdoor unit installation and construction ...
Page 111: ...Construction E 24 4 Outdoor unit installation and construction ...
Page 112: ...Construction E 25 4 Outdoor unit installation and construction ...
Page 113: ...Construction E 26 4 Outdoor unit installation and construction ...
Page 114: ...Construction E 27 4 Outdoor unit installation and construction ...
Page 115: ...Construction E 28 4 Outdoor unit installation and construction ...
Page 116: ...Construction E 29 4 Outdoor unit installation and construction ...
Page 117: ...Construction E 30 4 Outdoor unit installation and construction ...
Page 118: ...Construction E 31 4 Outdoor unit installation and construction ...
Page 119: ...Construction E 32 4 Outdoor unit installation and construction ...
Page 120: ...Construction E 33 4 Outdoor unit installation and construction ...
Page 121: ...Construction E 34 4 Outdoor unit installation and construction ...
Page 122: ...Construction E 35 4 Outdoor unit installation and construction ...
Page 123: ...Construction E 36 4 Outdoor unit installation and construction ...
Page 124: ...Construction E 37 4 Outdoor unit installation and construction ...
Page 127: ...Construction E 40 5 Commissioning ...
Page 128: ...Construction E 41 5 Commissioning ...
Page 129: ...Construction E 42 5 Commissioning ...
Page 130: ...Construction E 43 5 Commissioning ...
Page 131: ...Construction E 44 5 Commissioning ...
Page 132: ...Construction E 45 5 Commissioning ...
Page 133: ...Construction E 46 5 Commissioning ...
Page 134: ...Construction E 47 5 Commissioning ...
Page 135: ...Construction E 48 5 Commissioning ...
Page 136: ...Construction E 49 5 Commissioning ...
Page 137: ...Construction E 50 5 Commissioning ...
Page 138: ...Construction E 51 5 Commissioning ...
Page 139: ...Construction E 52 5 Commissioning ...
Page 140: ...Construction E 53 5 Commissioning ...
Page 141: ...Construction E 54 5 Commissioning ...
Page 142: ...Construction E 55 5 Commissioning ...
Page 143: ...Separately Contents 1 Parts for the outdoor unit 1 Exhaust extension kit F 2 F 1 ...
Page 150: ...Periodicinspection G 3 1 Periodic maintenance contract 70 90 Type 120 150 190 Type ...
Page 155: ...Water heat exchange unit H 5 3 External view ...
Page 158: ...Water heat exchange unit H 8 4 Specification 2 External dimension diagram ...
Page 161: ...Water heat exchange unit H 11 4 Specification ...