Remote Control Commands
R&S
®
Scope Rider RTH
463
User Manual 1326.1578.02 ─ 12
BUS:CAN:FRAMe<m>:SDATa?
Returns the complete symbolic data of the selected frame.
Suffix:
<m>
.
*
Return values:
<SymbolicData>
String with comma-separated list of symbolic data
Example:
BUS:CAN:FRAMe9:SDATa?
<-- [sym] 325 kW, 0x0A, 423 N, 174 l, Running, 90 degC, 0x06, 437 rpm
Returns the symbolic results of the 9th frame.
Usage:
Query only
BUS:CAN:FRAMe<m>:STARt?
BUS:CAN:FRAMe<m>:STOP?
Returns the start time and stop time of the selected frame.
Suffix:
<m>
.
*
Return values:
<FrameStart>
<FrameStop>
Time
Range:
-100E+24 to 100E+24
*RST:
0
Default unit: s
Usage:
Query only
BUS:CAN:FDATa:FRAMe<m>:STANdard?
Returns the CAN standard.
The setting is available in CAN FD option R&S
RTH-K9.
Suffix:
<m>
.
*
Return values:
<FrameStandard>
CAN | CANFd
*RST:
CAN
Usage:
Query only
BUS:CAN:FRAMe<m>:STATus?
Returns the overall state of the selected frame.
Protocol Analysis