Remote Control Commands
R&S
®
RTM3000
624
User Manual 1335.9090.02 ─ 08
Parameters:
<TxSource>
CH1 | CH2 | CH3 | CH4 | NONE | D0..D15
NONE
Disables the optional TX line.
*RST:
NONE
BUS<b>:UART:POLarity
<IdleState>
Defines the logic levels of the bus. The idle state corresponds to a logic 1, and the start
bit to a logic 0.
Suffix:
<b>
.
1..4
Parameters:
<IdleState>
IDLLow | IDLHigh
IDLLow: idle low, low = 1
IDLHigh: idle high, high = 1
*RST:
IDLH
BUS<b>:UART:DATA:POLarity
<Polarity>
Defines if the transmitted data on the bus is high (high = 1) or low (low = 1) active.
.
Suffix:
<b>
.
1..4
Parameters:
<Polarity>
POSitive | NEGative
POSitive = high active
NEGative = low active
*RST:
POS
BUS<b>:UART:SSIZe
<SymbolSize>
Sets the number of data bits in a message.
Suffix:
<b>
.
1..4
Parameters:
<SymbolSize>
Range:
5 to 9
Increment: 1
*RST:
8
Default unit: Bit