REFCurve<m>:VERTical:SCALe
<Scale>
Changes the vertical scale of the reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<Scale>
Default unit: V/div
REFCurve<m>:WCOLor
<WaveformColor>
Selects a color for the reference waveform. The default color is white. You can select
another monochrome color, or a color scale.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<WaveformColor>
YELLow | GREen | ORANge | BLUE | LBLUE | WHITE | CYAN |
PINK | RED | TEMPerature | RAINbow | FIRE | DEFault
*RST:
DEF
REFCurve<m>:LABel
<WaveformLabel>
Defines a label for the indicated reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameters:
<WaveformLabel>
String parameter
String parameter
Example:
REFCurve2:LABel "Origin"
Sets the label "Origin" for reference R2.
16.6.4
Search
.......................................................................................482
...................................................................................483
.................................................................................. 484
................................................................................... 486
Rise/Fall Time Search Configuration
.................................................................... 486
....................................................................................488
Data2Clock Search Configuration
.........................................................................489
Waveform Analysis
www.allice.de
Allice Messtechnik GmbH