Remote Control Commands
R&S
®
RTM3000
513
User Manual 1335.9090.02 ─ 08
RE1 | RE2 | RE3 | RE4
Active reference channels 1 to 4
D0..D15
Active digital channels D0...D15. Only available, if MSO option
R&S
RTM-B1 is installed.
<SignalSource2>
None | CH1..4 | MA1 | RE1..4 | D0..15
Second source waveform, which is required for delay and phase
mesurements ("Measure Source 2").
MEASurement<m>:DELay:SLOPe
<SignalSlope>,<ReferenceSlope>
Sets the edges to be used for delay measurement and delay to trigger measurement.
The associated waveforms are defined with
.
Parameters:
<SignalSlope>
POSitive | NEGative
Slope of first waveform ("Measure Source").
*RST:
POS
<ReferenceSlope>
POSitive | NEGative
Slope of the second waveform ("Measure Source 2"). The value
is ignored in delay to trigger measurements.
*RST:
POS
MEASurement<m>:DELay:DIRection
<Direction>,<Direction>
Selects the edges for delay measurement and delay to trigger measurement.
Suffix:
<m>
.
1..8
Selects the measurement place.
Parameters:
<Direction>
NEARest | FRFI | FRLA
For
delay measurement
, it defines the edge of the first wave-
form ("Measure Source").
NEARest: Nearest edge to the trigger point.
FRFI: First edge from the left window edge.
FRLA: First edge from the right window edge, which is the last
edge if counted from the left window edge.
For
delay to trigger measurement
, it defines the measured
edge.
NEARest: Nearest edge to the trigger point.
FRFI: Next edge from the trigger to the right.
FRLA: Next edge from the trigger to the left.
<Direction>
NEARest | FRFI | FRLA