Remote Control Commands
R&S
®
RTM3000
603
User Manual 1335.9090.02 ─ 08
Suffix:
<b>
.
1..4
Parameters:
<MosiPolarity>
ACTLow | ACTHigh
*RST:
ACTH
BUS<b>:SPI:MISO:POLarity
<MisoPolarity>
Selects whether transmitted data is high active (high = 1) or low active (low = 1) on the
MISO line.
Suffix:
<b>
.
1 | 3. Bus 2 or 4 is not available if the MISO source is used on
bus 1 or 3, respectively.
Parameters:
<MisoPolarity>
ACTLow | ACTHigh
*RST:
ACTH
BUS<b>:SPI:BORDer
<BitOrder>
Defines if the data of the messages starts with MSB (most significant bit) or LSB (least
significant bit).
Suffix:
<b>
.
1..4
Parameters:
<BitOrder>
MSBFirst | LSBFirst
*RST:
MSBFirst
BUS<b>:SPI:SSIZe
<SymbolSize>
Sets the word length, the number of bits in a message.
Suffix:
<b>
.
1..4
Parameters:
<SymbolSize>
Range:
4 to 32
Increment: 1
*RST:
8
Default unit: Bit
16.11.2.2
SPI (no CS) - Configuration
Start the bus configuration with the threshold setting. Use one of the following com-
mands:
●
CHANnel<m>:THReshold:FINDlevel
Serial Bus Analysis