Remote Control Commands
R&S
®
RTM3000
495
User Manual 1335.9090.02 ─ 08
SHORter
Triggers if the signal crosses vertical limits before the specified
"Width" time is reached.
LONGer
Triggers if the signal crosses vertical limits before the specified
"Width" time is reached.
*RST:
LONG
SEARch:TRIGger:WINDow:WIDTh
<Width>
Sets the reference pulse width, the nominal value for comparisons.
Parameters:
<Width>
*RST:
400e-6
16.6.4.10
Search Results
...............................................................................................495
......................................................................................... 495
SEARch:RESult:BCOunt?
Returns the maximum number of search results, which the instrument can store.
Return values:
<BufferedCount>
Maximum number of search results
Usage:
Query only
SEARch:RESDiagram:SHOW
<ResultShow>
Shows or hides the table of search results.
Parameters:
<ResultShow>
ON | OFF
*RST:
OFF
Example:
Chapter 16.2.3.1, "Searching for a Pulse of Specified Width"
Waveform Analysis
www.allice.de
Allice Messtechnik GmbH