Remote Control Commands
R&S
®
RTM3000
665
User Manual 1335.9090.02 ─ 08
is set to
TDM
), the polarity defines the
edge of the frame synchronization pulse that identifies the beginning of a frame.
Suffix:
<b>
.
1..4
Parameters:
<WordSelectPolarity> NORMal | INVert
NORMal
0 indicates the left channel, and 1 indicates the right channel.
This is the usual setting.
TDM: the frame begins with a rising edge. This is the usual set-
ting.
INVert
0 indicates the right channel, and 1 the left channel.
TDM: the frame begins with a falling edge.
*RST:
NORM
BUS<b>:I2S:WSELect:SOURce
<WordSelectSource>
Selects the source of the word select line.
Suffix:
<b>
.
1..4
Parameters:
<WordSelectSource> CH1 | CH2 | CH3 | CH4 | D0..15
CH3 and CH4 are only available with 4-channel R&S
RTM3000
oscilloscopes.
*RST:
CH1
BUS<b>:I2S:WSELect:THReshold
<Threshold>
Sets the threshold for the indicated audio line.
Suffix:
<b>
.
1..4
Parameters:
<Threshold>
s
*RST:
1.4
16.11.7.2
Audio Trigger
TRIGger:A:I2S:CHANnel:LEFT:CONDition
........................................................................666
TRIGger:A:I2S:CHANnel:LEFT:DMAX
..............................................................................666
TRIGger:A:I2S:CHANnel:LEFT:DMIN
............................................................................... 667
TRIGger:A:I2S:CHANnel:RIGHt:CONDition
...................................................................... 667
TRIGger:A:I2S:CHANnel:RIGHt:DMAX
............................................................................ 667
Serial Bus Analysis
www.allice.de
Allice Messtechnik GmbH