Remote Control Commands
R&S
®
RTM3000
666
User Manual 1335.9090.02 ─ 08
TRIGger:A:I2S:CHANnel:RIGHt:DMIN
..............................................................................667
TRIGger:A:I2S:CHANnel:TDM<n>:CONDition
...................................................................667
TRIGger:A:I2S:CHANnel:TDM<n>:DMAX
.........................................................................668
TRIGger:A:I2S:CHANnel:TDM<n>:DMIN
..........................................................................668
................................................................................................668
................................................................................................ 669
.....................................................................................669
..................................................................................... 669
................................................................................................669
BUS<b>:I2S:FCOunt?
Returns the number of decoded frames.
Suffix:
<b>
.
1..4
Return values:
<FrameCount>
Usage:
Query only
TRIGger:A:I2S:CHANnel:LEFT:CONDition
<Comparison>
Define the operators for comparison of the decoded data words with the specified data
words on the specified channel.
Parameters:
<Comparison>
OFF | EQUal | NEQual | GTHan | LTHan | INRange | OORange
INRange
: in range
OORange
: out of range
OFF
No range is defined.
EQUal | NEQual | GTHan | LTHan
Equal, not equal, greater than, less than. These conditions
require one data word to be set with
TRIGger:A:I2S:CHANnel:LEFT:DMAX
<MaximumValue>
Specifies the maximum data value to be found, if
is set to
INRange
or
OORange
Parameters:
<MaximumValue>
The data format is decimal. The maximum value is limited by the
word length. Consider that audio words are signed numbers in
2's complement format. For example, an 8-bit data word has a
value range from -128 to 127.
Serial Bus Analysis