SEARch:TRIGger:EDGE:SLOPe
<Slope>
Sets the slope to be searched for.
Parameters:
<Slope>
POSitive | NEGative | EITHer
*RST:
POS
SEARch:TRIGger:EDGE:LEVel
<Level>
Sets the voltage level for the edge search.
Parameters:
<Level>
*RST:
0.5 V
SEARch:TRIGger:EDGE:LEVel:DELTa
<DeltaLevel>
Sets a hysteresis range above and below the search level to avoid unwanted search
results caused by noise oscillation around the level.
Parameters:
<DeltaLevel>
Range:
Lower limit depends on vertical scale and other set-
tings, no upper limit
*RST:
0.2 V
16.6.4.3
Width Search Configuration
.................................................................................. 484
...................................................................................... 484
SEARch:TRIGger:WIDTh:LEVel:DELTa
............................................................................ 485
....................................................................................485
.....................................................................................485
..................................................................................... 485
SEARch:TRIGger:WIDTh:POLarity
<Polarity>
Indicates the polarity of the pulse to be searched for.
Parameters:
<Polarity>
POSitive | NEGative
*RST:
POS
Example:
Chapter 16.2.3.1, "Searching for a Pulse of Specified Width"
SEARch:TRIGger:WIDTh:LEVel
<Level>
Sets the voltage level on which the pulse width is measured.
Parameters:
<Level>
*RST:
500 mV