496
Rockwell Automation Publication 193-UM015D-EN-P - November 2013
Appendix B
Parameter List
Analog3 Setup
(Continued)
508
InAnMod3Ch01Type
C.Analog3.Ch01InputRangeType_0
C.Analog3.Ch01InputRangeType_1
C.Analog3.Ch01InputRangeType_2
C.Analog3.Ch01InputRangeType_3
C.Analog3.Ch01InputRangeType_4
Assignment for
Analog Module 3
Input Channel 01
function
USINT
1
1
0= Disabled
1= 4To20mA
2= 0To20mA
3= 0To10Volts
4= 1To5Volts
5= 0To5Volts
6= 100Pt385
7= 200Pt385
8= 500Pt385
9= 1000Pt385
10=100Pt3916
11= 200Pt3916
12= 500Pt3916
13= 1000Pt3916
14= 10Cu426
15= 120Ni618
16= 120Ni672
17= 604NiFe518
18= 150ohm
19= 1000ohm
20 = 3000ohm
21= 6000ohm
0
509
InAMod3Ch1Format
C.Analog3.Ch01InputFormat_0
C.Analog3.Ch01InputFormat_1
C.Analog3.Ch01InputFormat_2
Assignment for
Analog Module 3
Input Channel 01
Data Format
USINT
1
1
0= EngUnits
1= EngUnitsTimes10
2= RawProportional
3= ScaledForPID
0
510
InAMod3C1TmpUnit
C.Analog3.Ch01InputTempMode
Assignment for
Analog Module 3
Input Channel 01
Temperature Units
USINT
1
1
0=DegreesC
1=DegreesF
0
511
InAMod3C1FiltFrq
C.Analog3.Ch01InputFilter_0
C.Analog3.Ch01InputFilter_1
C.Analog3.Ch01InputFilter_2
Assignment
Analog Module 3
Input Channel 01
Filter Freq
USINT
1
1
0=17Hz
1=4Hz
2=62Hz
3=470Hz
0
512
InAMod3C1OpCktSt
C.Analog3.Ch01InputOpenWire_0
C.Analog3.Ch01InputOpenWire_1
Indicates Analog
Module 3 Input
Channel 01 Open
Circuit State
USINT
1
1
0=Upscale
1=Downscale
2=Zero
0
513
InAnMod3Ch1RTDEn
C.Analog3.Ch01InputTwoWireRTD
Enable Analog
Module 3 Input
Channel 01 to
function with RTD
BOOL
1
1
0=3-wire
1=2-wire
0
514
InAMod3C1TripDly
C.Analog3.Ch01InputTripDelay
Analog Module 3
Input Channel 01
Trip Delay
USINT
1
10
0
250
10
Second
s
515
InAMod3C1TripLvl
C.Analog3.Ch01InputTripLimit
Level (in selected
Units) where
Analog Input
generates a trip
UINT
2
1
-32768
32767
0
516
InAMod3C1WarnLvl
C.Analog3.Ch01InputWarnLimit
Level (in selected
Units) where
Analog Input
generates a
warning
UINT
2
1
-32768
32767
0
517
InAnMod3Ch02Type
C.Analog3.Ch02InputRangeType_0
C.Analog3.Ch02InputRangeType_1
C.Analog3.Ch02InputRangeType_2
C.Analog3.Ch02InputRangeType_3
C.Analog3.Ch02InputRangeType_4
Assignment for
Analog Module 3
Input Channel 02
function
USINT
1
1
0= Disabled
1= 4To20mA
2= 0To20mA
3= 0To10Volts
4= 1To5Volts
5= 0To5Volts
6= 100Pt385
7= 200Pt385
8= 500Pt385
9= 1000Pt385
10=100Pt3916
11= 200Pt3916
12= 500Pt3916
13= 1000Pt3916
14= 10Cu426
15= 120Ni618
16= 120Ni672
17= 604NiFe518
18= 150ohm
19= 1000ohm
20 = 3000ohm
21= 6000ohm
0
Group
Param
No.
Parameter Name
Device Profile Tag Name
Description
Type
Data Size
(bytes)
Scale
Factor
Min
Max
Default Units
Summary of Contents for Allen-Bradley E300
Page 1: ...E300 Electronic Overload Relay Bul 193 592 User Manual...
Page 128: ...128 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 5 Operating Modes...
Page 304: ...304 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 7 Commands Notes...
Page 502: ...502 Rockwell Automation Publication193 UM015D EN P November 2013 Appendix B Parameter List...
Page 545: ......