PCP - 04 TIME RELAY
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL
sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com,
e-mail:
APPERANCE
FEATURES
DESCRIPTION
ی 8 operating modes,
ی Relay state and time counting indica
-
tor – LED,
ی Triggered by means of power supply
voltage or control input in dependence
of set operating mode,
ی High accuracy of time measure,
ی Relay output – one changeover
contact, 5 A maximum load,
ی Casing designed for mounting in
a junction box.
The PCP-04 multifunction relay is de
-
signed for timing function implementation
in automatics and control systems. Both
power supply voltage and control input
trigger the relay. The PCP-04 relay is
capable of operating in 8 independent op
modes which may be triggered by means
of either power supply voltage or external
trigger impulse (from either L or N wires).
It is possible to adjust time within very
wide range. The device is fitted with the
relay state indicator – the LED. It is pos
-
sible to mount the device in the 60 mm
junction box.
TECHNICAL DATA
PCP- 04
Power terminals: L (black), N (blue)
Rated voltage: 230 V
~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 15,5 mA
External trigger terminal: IN (triggered from L or N line)
Trigger current: 510 μA
Op modes quantity:
8
t time adjustment range: 0,1 s ÷ 10 days (servo + continuous)
Time measure accuracy: 0,2 %
Relay state and time measure indicator:
red LED
Relay contacts parameters: 1NO5 A / 250 V AC1 1250 VA (voltage contact)
Connection terminals / leads quantity:
4
Connection wire section: 1 mm
2
Operating temperature: -20 ÷ +60
o
C
Operating position: optional
Casing fastening: 60 mm junction box
Casing IP: IP20 (PN-EN 60529)
Protection class:
II
Overvoltage category:
II
Pollution level: 2
Dimensions: 50 x 50 x 15 mm
Weight: 30 g
Standard conformity: PN-EN 60730-1
PN-EN 60730-2-7
PN-EN 61000-4-2,3,4,5,6,11
Load / time measure indicator
Load power supply lead (P)
Power lead (L)
Operating mode selection
Trigger lead (IN)
ON-time setting
Time range selection
Power lead (N)
b
r
o
w
n
r
ed
b
l
a
ck
b
l
ue
The timer should be
connected to a single-
phase system accordin
-
gly to current standards.
The device connections
will be described in this
manual. Only qualified electricians are
allowed to assembly, connect and ad
-
just the timer. It is necessary to read this
manual before the timer mounting. Do
not disassembly the timer casing or you
will lose any warranty rights and expo
-
se yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network. The timer
should be carried, stored and used in
an appropriate way. Do not mount the
timer in case of any device parts lack,
damage or deformation. In case of mal
-
function please notify the manufacturer.
CAUTION