Chapter 8
Metering and Diagnostics
37
Under Reactive Power Generated (-kVAR) condition detected
38
Over Reactive Power Generated (-kVAR) condition detected
39
Total Apparent Power (kVA) is below warning level
40
Total Apparent Power (kVA) exceeded warning level
41
Under Total Power Factor Lagging (-PF) condition detected
42
Over Total Power Factor Lagging (-PF) condition detected
43
Under Total Power Factor Leading (+PF) condition detected
44
Over Total Power Factor Leading (+PF) condition detected
50
PTC input indicates that the motor stator windings overheated
51
DeviceLogix defined warning was generated
56
Invalid parameter config. See parameters 38-39 for details
58
DeviceLogix Feedback Timeout Trip was detected
60
Number of Starts Warning Level Exceeded
61
Operating Hours Warning Level Exceeded
65
Input Channel 00 on Analog Module 1 exceeded its Warning Level
66
Input Channel 01 on Analog Module 1 exceeded its Warning Level
67
Input Channel 02 on Analog Module 1 exceeded its Warning Level
68
Input Channel 00 on Analog Module 2 exceeded its Warning Level
69
Input Channel 01 on Analog Module 2 exceeded its Warning Level
70
Input Channel 02 on Analog Module 2 exceeded its Warning Level
71
Input Channel 00 on Analog Module 3 exceeded its Warning Level
72
Input Channel 01 on Analog Module 3 exceeded its Warning Level
73
Input Channel 02 on Analog Module 3 exceeded its Warning Level
74
Input Channel 00 on Analog Module 4 exceeded its Warning Level
75
Input Channel 01 on Analog Module 4 exceeded its Warning Level
76
Input Channel 02 on Analog Module 4 exceeded its Warning Level
81
Digital Expansion Module 1 is not operating properly
82
Digital Expansion Module 2 is not operating properly
83
Digital Expansion Module 3 is not operating properly
84
Digital Expansion Module 4 is not operating properly
85
Analog Expansion Module 1 is not operating properly
86
Analog Expansion Module 2 is not operating properly
87
Analog Expansion Module 3 is not operating properly
88
Analog Expansion Module 4 is not operating properly
90
Control Module installed does not match the expected type
91
Sensing Module installed does not match the expected type
92
Comms Module installed does not match the expected type
93
Operator Station installed does not match expected type
94
Digital Module installed does not match the expected type
95
Analog Module installed does not match the expected type
98
A hardware fault condition was detected
Warning History Code Description
Summary of Contents for Allen-Bradley E300
Page 1: ...E300 Electronic Overload Relay Bul 193 592 User Manual...
Page 128: ...128 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 5 Operating Modes...
Page 304: ...304 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 7 Commands Notes...
Page 502: ...502 Rockwell Automation Publication193 UM015D EN P November 2013 Appendix B Parameter List...
Page 545: ......