Rockwell Automation Publication 193-UM015D-EN-P - February 2015
477
Parameter List
Appendix
B
Options Setup
(Continued)
224
OperStationType
Select Operator
Station Type
USINT
1
1
0= IgnoreType
1= NoStation
2= ControlStation
3= DiagStation
0
225
DigitalMod1Type
Select Digital I/O
Expansion Module
1 Type
USINT
1
1
0= IgnoreType
1=NoModule
2=4In2Out24VDC
3=4In2Out120VAC
4=4In2Out240VAC
0
226
DigitalMod2Type
Select Digital I/O
Expansion Module
2 Type
USINT
1
1
0= IgnoreType
1=NoModule
2=4In2Out24VDC
3=4In2Out120VAC
4=4In2Out240VAC
0
227
DigitalMod3Type
Select Digital I/O
Expansion Module
3 Type
USINT
1
1
0= IgnoreType
1=NoModule
2=4In2Out24VDC
3=4In2Out120VAC
4=4In2Out240VAC
0
228
DigitalMod4Type
Select Digital I/O
Expansion Module
4 Type
USINT
1
1
0= IgnoreType
1=NoModule
2=4In2Out24VDC
3=4In2Out120VAC
4=4In2Out240VAC
0
229
AnalogMod1Type
Select Analog I/O
Expansion Module
1 Type
USINT
1
1
0=IgnoreType
1=NoModule
2=3In1OutAnalog
0
230
AnalogMod2Type
Select Analog I/O
Expansion Module
2 Type
USINT
1
1
0=IgnoreType
1=NoModule
2=3In1OutAnalog
0
231
AnalogMod3Type
Select Analog I/O
Expansion Module
3 Type
USINT
1
1
0=IgnoreType
1=NoModule
2=3In1OutAnalog
0
232
AnalogMod4Type
Select Analog I/O
Expansion Module
4 Type
USINT
1
1
0=IgnoreType
1=NoModule
2=3In1OutAnalog
0
233
MismatchAction
Select Mismatched
Module Actions
0=warning 1=
fault
UINT
1
1
Bit0= ControlModule
Bit1= SensingModule
Bit2= CommsModule
Bit3= OperatorStation
Bit4= DigitalModule1
Bit5= DigitalModule2
Bit6= DigitalModule3
Bit7= DigitalModule4
Bit8= AnalogModule1
Bit9= AnalogModule1
Bit10= AnalogModule1
Bit11= AnalogModule1
0
234
Reserved
235
Reserved
236
Reserved
237
Reserved
238
Reserved
Current Setup
239
PLInhibitTime
C.PhaseLossInhibitTime
Phase Loss Inhibit
Time
USINT
1
1
0
250
0
Second
s
240
PLTripDelay
C.PhaseLossTripDelay
Phase Loss Trip
Delay
USINT
1
10
1
250
10
Second
s
241
GroundFaultType
C.GroundFaultType
Select Ground
Fault Type
USINT
1
1
0= Disabled
1= Internal1to5Amps
2= ExtPt02toPt1Amps
3= ExtPt1toPt5Amps
4= ExtPt5to1Amps
5= External1to5Amps
0
242
GFInhibitTime
C.GroundFaultInhibitTime
Ground Fault
Inhibit Time
USINT
1
1
0
250
10
Second
s
243
GFTripDelay
C.GroundFaultTripDelay
Ground Fault Trip
Delay
USINT
1
10
0
250
5
Second
s
Group
Param
No.
Parameter Name
Device Profile Tag Name
Description
Type
Data Size
(bytes)
Scale
Factor
Min
Max
Default Units
Summary of Contents for Allen-Bradley E300
Page 1: ...E300 Electronic Overload Relay Bul 193 592 User Manual...
Page 128: ...128 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 5 Operating Modes...
Page 304: ...304 Rockwell Automation Publication 193 UM015D EN P February 2015 Chapter 7 Commands Notes...
Page 502: ...502 Rockwell Automation Publication193 UM015D EN P November 2013 Appendix B Parameter List...
Page 545: ......