background image

Z-Wave Mutil-relay

Federal Communications Commission (FCC) Statement

FCC Caution: Any changes or modifications not expressly approved by the party responsible for

compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any

interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

against harmful interference in a residential installation. This equipment generates, uses and can

radiate radio frequency energy and, if not installed and used in accordance with the instructions,

may caus harmful interference to radio communications.However, there is no guarantee that

interference will not occur in a particular installation. If this equipment does cause harmful interference

to radio or television reception, which can be determined by turning the equipment off and on,

the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.Increase the separation between the equipment and

receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver

is connected.Consult the dealer or an experienced radio/TV technician for help.This equipment

Z-Wave Mutil-relay

should be installed and operated with minimum distance 20cm between the radiator and your body.

IC Caution:

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject

to the following two conditions: (1) this device may not cause interference, and (2) this device must

accept any interference, including interference that may cause undesired

operation of the device.

DECLARATION DE CONFORMITE D'INDUSTRIE CANADA

Ce périphérique a été testé et reconnu conforme aux limites spécifiées dans RSS-210.

Son utilisation est soumise aux deux conditions suivantes :

(1) il ne doit pas provoquer d'interférences gênantes et

(2) il doit tolérer les interférences re.ues, notamment cellessusceptibles d'en perturber le fonctionnement.

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for 
a period of two years from the original date of consumer purchase. This warranty is limited 
to the repair or replacement of this product only and does not extend to consequential or
incidental damage to other products that may be used with this product.

 

This warranty is in lieu of all other warranties, expressed or implied. Some states do not 
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
 of incidental or consequential damage, so the above limitations may not apply to you. 

This warranty gives you specific rights, and you may also have other rights which vary from 
state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS  

WARNING

Model:ZW12

RISK OF FIRE

Power: 120 VAC, 60 Hz.

RISK OF ELECTRICAL SHOCK

Signal (Frequency): 908.42 MHZ.

RISK OF BURNS

Maximum load for outlet 500W Resistive

CONTROLLING APPLIANCES:

Maximum load for the Z-Wave™ controlled outlet:

EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL 

APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT

Range: Up to 100 feet line of sight between the Wireless Controller

ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION

and the closest Z-Wave™ receiver module.

 MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES

Operating Temperature Range: 32-104° F (0-40° C)

MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. 

 DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL 

Specifications subject to change without notice

OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE

due to continuing product improvement

 REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE

 

THE FOLLOWING:

Website:www.nie-tech.com

DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC

 

HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT

 

A HAZARDOUS CONDITION DUE TO UNATTENDED OR

 

UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Summary of Contents for ZW12

Page 1: ...conforme aux limites spécifiées dans RSS 210 Son utilisation est soumise aux deux conditions suivantes 1 il ne doit pas provoquer d interférences gênantes et 2 il doit tolérer les interférences re ues notamment cellessusceptibles d en perturber le fonctionnement WARRANTY Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date o...

Page 2: ...s 5x change led parameter Function 5 press 4x then LED lit for 4s within this time press 4x again LED blinks 3 times then off to FACTORY RESET Node Please use this procedure only when the network primary controller is missing or otherwise inoperable Adding Your Device To A Hub The device support two methods of inclusion When using a Z Wave Plus certified controller choose Network Wide Inclusion or...

Page 3: ...par 4 to 9 5 LED indicator Paramter No 5 0x05 Size 1 Byte default 0 Value 00 led OFF when output ON led ON when output OFF Value 01 led ON when output ON led OFF when output OFF Value 02 led always OFF Value 03 led always ON 6 EP1 Auto Turn off Timer only switch 1 type 4 Paramter No 6 0x06 Size 4 Byte default 0 Value 00 timer disabled Value 1 65535 This Timer Turn off 7 EP1 Auto Turn on Timer only...

Page 4: ...or Report Notification Report Device Reset Locally Notification Sensor Binary Report Association group_2 basic set command on off controlt When the output of the ZW12 is changed On 0xFF or Off 0x00 The ZW12 will automatically send out a related basic set command On 0xFF or Off 0x00 to its associated group Association group_3 basic set command on off controlt When the output of the ZW12 is changed ...

Reviews: