Remote Control Commands
R&S
®
SMB100A
425
Operating Manual 1407.0806.32 ─ 21
[:SOURce<hw>]:SWEep:POWer:DWELl
<Dwell>
Sets the time taken for each level step of the sweep.
Tip:
It is recommended to switch off the "Display Update" for optimum sweep perform-
ance especially with short dwell times (
Parameters:
<Dwell>
float
Range:
1E-3 to 100
Increment: 100E-6
*RST:
15E-3
Example:
SWE:POW:DWEL 12 ms
sets a dwell time of 12 ms for a level sweep at the RF output.
Manual operation:
See
[:SOURce<hw>]:SWEep:POWer:EXECute
Triggers a sweep.
The command is only valid for sweep mode Single (
SOURce:SWEep:POWer:MODE
SINGle
). The command corresponds to the manual-control command "Execute Single
Sweep".
Example:
SOURce:SWEep:POWer:MODE SINGle
sets the single cycle mode of the level sweep.
SWE:POW:EXEC
triggers a level sweep at the RF output.
Usage:
Event
Manual operation:
See
"Execute Single Sweep - Level Sweep"
[:SOURce<hw>]:SWEep:POWer:MODE
<Mode>
Sets the cycle mode of the level sweep.
SOURce Subsystem