Remote Control Commands
R&S
®
SMB100A
394
Operating Manual 1407.0806.32 ─ 21
Manual operation:
See
[:SOURce<hw>]:PULM:STATe
<State>
Activates the pulse modulation.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
PULM:STAT ON
activates pulse modulation.
Options:
R&S SMB-K21 or R&S SMB-K22 (Pulse Modulator)
Manual operation:
See
[:SOURce<hw>]:PULM:TRAin:CATalog?
Queries a list of available pulse train files. The individual pulse train files are separated
by commas.
The files are stored with the fixed file extensions
*.pulstrn
in a directory of the
user's choice. The directory applicable to the commands is defined with the command
MMEMory:CDIR
.
Return values:
<Catalog>
string
Example:
MMEM:CDIR '/var/user/Lists'
selects the directory for the pulse train files.
PULM:TRA:CAT?
queries the available files.
Response: 'P_CONS','P_INCR','P_DECR'
the lists
P_CONS
,
P_INCR
and
P_DECR
are available.
Usage:
Query only
Options:
R&S SMB-K27 (Pulse Train)
Manual operation:
See
"Pulse Train Data – Pulse Generator"
[:SOURce<hw>]:PULM:TRAin:DELete
<Filename>
Deletes the specified pulse train file.
The files are stored with the fixed file extensions
*.pulstrn
in a directory of the
user's choice. The directory applicable to the command is defined with the command
MMEMory:CDIR
. To access the files in this directory, only the file name has to be given
without the path and the file extension.
Setting parameters:
<Filename>
<list file name>
SOURce Subsystem