Remote Control Commands
R&S
®
SMB100A
395
Operating Manual 1407.0806.32 ─ 21
Example:
MMEM:CDIR '/var/user/Lists'
selects the directory for the pulse train files.
PULM:TRA:DEL 'P_FIVE'
deletes the list
P_FIVE
Usage:
Setting only
Options:
R&S SMB-K27 (Pulse Train)
Manual operation:
See
"Pulse Train Data – Pulse Generator"
[:SOURce<hw>]:PULM:TRAin:OFFTime
<OffTime>
Fills the Off-time part of the selected file with data.
*RST does not affect data lists.
Parameters:
<OffTime>
Offtime#1{, Offtime#2, ...} | binary block data
The data can be given either as a list of numbers (list can be of
any length and list entries must be separated by commas) or as
binary block data.
When block data is transferred, 8 (4) bytes are always interpre-
ted as a floating-point number with double accuracy (see the
command
FORMat:DATA
).
The maximum length is 2047 values.
Example:
MMEM:CDIR '/var/user/Lists'
selects the directory for the pulse train files.
PULM:TRA:SEL 'P_INCR'
selects
P_INCR
for editing.
P_INCR
is created if it does not yet
exist.
PULM:TRA:OFFT 10ns,30ns,40ns,...
specifies the off-time values in
P_INCR
. If the list already con-
tains data, it is overwritten.
Options:
R&S SMB-K27 (Pulse Train)
Manual operation:
See
[:SOURce<hw>]:PULM:TRAin:OFFTime:POINts?
Queries the length (in points) of the off-time component of the selected list.
Return values:
<Points>
integer
Range:
0 to 2047
*RST:
0
SOURce Subsystem