Overheating
Overheating is a potentially serious condition because the
excessively high temperatures can lead to disk drive failure and
controller malfunction.
Overheating usually results from:
•
Fan failure
•
Poor air circulation around the enclosure
WebPAM PROe reports failed fans along with elevated
temperature. On VTrak, there are two kinds of fans:
•
Power supply, 1 fan each, 2 fans total
•
Cooling units, 2 fans each
If a power supply fan fails, you must replace the power supply. If
a cooling unit fan fails, you can remove the cooling unit and
replace only the fan itself.
No tools are required for either procedure. See page 221 for
instructions on replacing the fans.
Air circulation around the VTrak enclosure may be a more
complex problem. Use the thermometer icons to help you locate
the specific hot spot. Check for these conditions:
•
Accumulated dust or objects blocking the fans
•
Less than a minimum of 5 inches (13 cm) space between the
back of the VTrak and the wall or other object
•
Ambient temperature above 95°F (35°C) where the VTrak is
operating
To cool down a VTrak, do the following:
•
Correct any problems identified above
•
Power it down and let it sit for an hour or longer
Summary of Contents for VTrack M-Class M200f
Page 18: ...VTrak M Class Product Manual 10 ...
Page 36: ...VTrak M Class Product Manual 28 ...
Page 61: ...Chapter 3 Setup 53 13 When you have finished specifying logical drives click the Next button ...
Page 64: ...VTrak M Class Product Manual 56 ...
Page 164: ...VTrak M Class Product Manual 156 ...
Page 246: ...VTrak M Class Product Manual 238 ...
Page 304: ...VTrak M Class Product Manual 296 ...