VTrak M-Class Product Manual
230
Replace Cache Battery – M500f/i/p
The cache battery is located in the Cooling Unit 1 (the left one). The battery is
replaced as an individual part. No tools are required for this procedure.
Note that the Battery LED on Cooling Unit 2 is always dark.
To replace a cache battery, do the following:.
1.
Verify that the battery LED is amber or red (above).
Cautions
•
Try reconditioning the battery before you replace it. See
“Battery” on page 120 for more information.
•
Installing an incorrect replacement battery may result in an
explosion.
•
Dispose of used batteries according to the instructions that
accompany the battery.
•
While the battery is removed, your system will be vulnerable
to a power failure. Temporarily set your cache policy to write-
through before starting this procedure. See “Logical Drive
Settings” on page 144 (WebPAM PROe) or “Logical Drive
Settings and Functions” on page 189. (CLU).
•
If power service has failed, do not remove the cooling unit if
the Controller’s Dirty Cache LED is flashing. See “Unsaved
Data in the Controller Cache” on page 295.
Battery LED
Summary of Contents for VTrack M-Class M200f
Page 18: ...VTrak M Class Product Manual 10 ...
Page 36: ...VTrak M Class Product Manual 28 ...
Page 61: ...Chapter 3 Setup 53 13 When you have finished specifying logical drives click the Next button ...
Page 64: ...VTrak M Class Product Manual 56 ...
Page 164: ...VTrak M Class Product Manual 156 ...
Page 246: ...VTrak M Class Product Manual 238 ...
Page 304: ...VTrak M Class Product Manual 296 ...