- 121 -
PB-00
Swing setting mode
Factory default
0
Set range
0: relative to center frequency 1: relative to maximum
frequency
Use this parameter to determine the reference for the swing.
0: relative center frequency (P0-07 frequency source), for the variable swing
system. The swing varies with the center frequency (set frequency).
1: relative maximum frequency (P0-10), for the fixed swing system, swing fixed.
PB-01
Wobble amplitude
Factory default
0.0%
Set range
0.0%
~
100.0%
PB-02
Sudden jump frequency
range
Factory default
0.0%
Set range
0.0%
~
50.0%
Use this parameter to determine the value of the swing value and the sudden jumper
frequency.
When setting the swing relative to the center frequency (PB-00 = 0), the swing AW =
frequency source P0-07 × swing amplitude PB-01. When setting the swing relative to the
maximum frequency (PB-00 = 1), the swing AW = maximum frequency P0-10 × swing
amplitude PB-01.
The frequency of the bounce frequency is the percentage of the frequency of the bounce
frequency relative to the swing when the wobble frequency is run. If the swing is selected
relative to the center frequency (PB-00 = 0), the sudden frequency is the change value. If
the swing is selected relative to the maximum frequency (PB-00 = 1), the spurious
frequency is a fixed value.
The frequency of the wobble is limited by the upper and lower frequencies.
PB-03
Wobble cycle
Factory default
10.0s
Set range
0.0s
~
3000.0s
PB-04
Triangular wave rise
time coefficient
Factory default
50.0%
Set range
0.0%
~
100.0%
Wobble cycle: the time value of a complete wobble cycle.
The triangular wave rise time coefficient PB-04 is the percentage of time that the triangular
wave rise time is relative to the wobble cycle PB-03. Triangle wave rise time = wobble
cycle PB-03 × triangular wave rise time coefficient PB-04, in seconds.
Triangle wave fall time = wobble cycle PB-03 × (1-triangular wave rise time factor PB-
04) in seconds.
PB-05
Set length
Factory default
1000m
Set range
0m
~
65535m
PB-06
Actual length
Factory default
0m
Set range
0m
~
65535m
PB-07
Number of pulses per
meter
Factory default
100.0
Set range
0.1
~
6553.5