- 37 -
P4-27
AI3 filter time
0.00s
~
10.00s
0.10s
☆
P4-28
Pulse min. input
0.00kHz
~
P4-30
0.00kHz
☆
P4-29
Corresponding percentage of
pulse min. input
-100.0%
~
100.0%
0.0%
☆
P4-30
Pulse max. input
P4-28
~
100.00kHz
50.00kHz
☆
P4-31
Corresponding percentage of
Pulse max. input
-100.0%
~
100.0%
100.0%
☆
P4-32
Pulse filter time
0.00s
~
10.00s
0.10s
☆
Function
Code
Name
Set Range
default
Alteration
P4-33
AI curve selection
Bit: AI1 curve selection
1: curve 1 (2 points, see P4-13
~ P4-16)
2: Curve 2 (2 points, see P4-18
~ P4-21)
3: curve 3 (2 points, see P4-23
~ P4-26)
4: curve 4 (4 points, see A6-00
~ A6-07)
5: curve 5 (4 points, see A6-08
~ A6-15)
Ten: AI2 curve selection, ibid
Hundreds: AI3 curve selection,
ibid
321
☆
P4-34
Setting selection when AI less
than min. input
Bit: AI1 is lower than the
minimum input setting
0: corresponds to the minimum
input setting
1: 0.0%
Ten: AI2 is lower than the
minimum input setting, ibid
Hundreds: AI3 is lower than the
minimum input setting, ibid
000
☆
P4-35
S1 delay
0.0s
~
3600.0s
0.0s
★
P4-36
S2 delay
0.0s
~
3600.0s
0.0s
★
P4-37
S3 delay
0.0s
~
3600.0s
0.0s
★