- 87 -
Set range
1
:
curve 1
(
2 point
,
see P4-13
~
P4-16
)
2
:
curve 2
(
2 point
,
see P4-18
~
P4-21
)
3
:
curve 3
(
2 point
,
see P4-23
~
P4-26
)
4
:
curve 4
(
4 point
,
see A6-00
~
A6-07
)
5
:
curve 5
(
4 point
,
see A6-08
~
A6-15
)
Ten
AI2 curve choose
(
1
~
5
,
same as above
)
Hundred
AI3 curve choose
(
1
~
5
,
same as above
)
The function code of the bit, ten, hundreds of bits were used to select, analog input AI1,
AI2, AI3 corresponding to the set curve. 3 Each of the five types of curves can be selected
for each analog input.
Curve 1, curve 2, curve 3 are 2-point curve, set in the P4 group function code, and curve
4 and curve 5 are 4-point curve, need to set in the A6 group function code.
P4-34
AI Below minimum input
setting selection
Factory
value
000
Set range
Bit
AI1 Below minimum input setting selection
0
:
Corresponds
to
the
minimum
input
setting
1
:
0.0%
Ten AI2 Below minimum input setting selection
(
0
~
1
,
same as above
)
hundred AI3 Below minimum input setting selection
(
0
~
1
,
same as above
)
The function code is used to set the setting of the analog quantity when the analog input
voltage is less than the set "minimum input".
The function code of the bit, ten, hundred, respectively, corresponding to the analog input
AI1, AI2, AI3.
If the option is 0, when the AI input is lower than the "minimum input", the corresponding
setting of the analog quantity is the curve "minimum input corresponding setting" (P4-14,
P4-19, P4- twenty four).
If 1 is selected, the analog value is set to 0.0% when the AI input is below the minimum
input.
P4-35
S1 delay time
Factory
default
0.0s
Set range
0.0s
~
3600.0s
P4-36
S2 delay time
Factory
default
0.0s
Set range
0.0s
~
3600.0s
P4-37
S3 delay time
Factory
default
0.0s
Set range
0.0s
~