- 44 -
P8-05
Acceleration time 3
0.0s to 6500.0s
Model
dependent
☆
P8-06
Deceleration time 3
0.0s to 6500.0s
Model
dependent
☆
P8-07
Acceleration time 4
0.0s to 6500.0s
0.0s
☆
P8-08
Deceleration time 4
0.0s to 6500.0s
0.0s
☆
P8-09
Frequency jump 1
0.00 Hz to max. frequency
0.00 Hz
☆
P8-10
Frequency jump 2
0.00 Hz to max. frequency
0.00 Hz
☆
P8-11
Frequency jump band
0.00 Hz to max. frequency
0.00 Hz
☆
P8-12
Forward/Reverse run switch
over
dead-zone time
0.0s to 3000.0s
0.0s
☆
P8-13
Reverse RUN selection
0, 1
0
☆
P8-14
Running mode when frequency
reference lower than frequency
lower limit
0 to 2
0
☆
P8-15
Droop rate
0.00% to 100.00%
0.00%
☆
P8-16
Accumulative power-on time
threshold
0 to 65000 h
0 h
☆
P8-17
Accumulative running time
threshold
0 to 65000 h
0 h
☆
P8-18
Startup protection selection
0, 1
0
☆
P8-19
Frequency detection value 1
0.00 Hz to max. frequency
50.00 Hz
☆
P8-20
Frequency detection hysteresis
1
0.0% to 100.0%
5.0%
☆
P8-21
Detection width of target
frequency reached
0.0% to 100.0%
0.0%
☆
P8-22
Jump frequency function
0, 1
0
☆
P8-25
Switchover frequency of accel
time 1 and accel time 2
0.00 Hz to max. frequency
0.00 Hz
☆
P8-26
Switchover frequency of decel
time 1 and decel time 2
0.00 Hz to max. frequency
0.00 Hz
☆
P8-27
Set highest priority to terminal
JOG function
0, 1
0
☆
P8-28
Frequency detection value
(
FDR2
)
0.00 Hz to max. frequency
50.00 Hz
☆
P8-29
Frequency detection hysteresis
(
FDT2
)
0.0% to 100.0%
5.0%
☆
P8-30
Detection of frequency 1
0.00 Hz to max. frequency
50.00 Hz
☆