- 48 -
Group PA: PID Function
Functio
n Code
Name
Set Range
default
change
PA-00
PID
reference
setting
channel
0 to 6
0
☆
PA-01
PID digital setting
0.0% to 100.0%
50.0%
☆
PA-03
PID operation direction
0, 1
0
☆
PA-04
PID
reference
and
Feedback range
0 to 65535
1000
☆
PA-05
Proportional gain Kp1
0.0 to 1000.0
20.0
☆
PA-06
Integral time Ti1
0.01s to 10.00s
2.00s
☆
PA-07
Differential time Td1
0.000s to 10.000s
0.000s
☆
PA-08
PID output limit in reverse
direction
0.00 Hz to max.
frequency
0.00 Hz
★
PA-09
PID error limit
0.0% to 100.0%
0.0%
☆
P9-54
Frequency selection for
continuing
to run upon fault
0 to 4
0
☆
P9-55 Backup frequency upon fault
0.0% to 100.0% (max.
frequency)
100.0%
☆
P9-59
Power dip ride-through
function
selection
0 to 2
0
★
P9-60
Threshold of power dip ride
through function disabled
80% to 100%
85%
★
P9-61
Judging time of bus voltage
recovering from power dip
0.0s to 100.0s
0.5s
★
P9-62
Threshold of power dip ride
through function enabled
60% to 100%
80%
★
P9-63 Load lost protection
0: Disabled
1: Enabled
0
☆
P9-64 Load lost detection level
0.0% to 100.0%
10.0%
☆
P9-65 Load lost detection time
0.0s to 60.0s
1.0s
☆
P9-67 Overspeed detection level
0.0% to 50.0% (max.
frequency)
20.0%
☆
P9-68 Overspeed detection time
0.0s to 60.0s
1.0s
☆
P9-69 Detection level of speed error
0.0% to 50.0% (max.
frequency)
20.0%
☆
P9-70 Detection time of speed error 0.0s to 60.0s
5.0s
☆
P9-71
Power dip ride-through gain
Kp
0 to 100
40
☆
P9-72
Power dip ride-through integral
coefficient
0 to 100
30
☆
P9-73
Deceleration time of power dip
ride-through
0.0s to 300.0s
20.0s
★