- 53 -
A2-07
Rotor resistance
0.001 to 65.535 Ω (AC drive
power ≤ 55 kW)
0.0001 to 6.5535 Ω (AC
drive power > 55 kW)
Auto-
tuning
dependent
★
A2-08
Leakage inductive reactance
0.01 to 655.35 mH (AC
drive power ≤ 55 kW)
0.001 to 65.535 mH (AC
drive power > 55 kW)
Auto-
tuning
dependent
★
A2-09
Mutual inductive reactance
0.1 to 6553.5 mH (AC drive
power ≤ 55 kW)
0.01 to 655.35 mH (AC
drive power > 55 kW)
Auto-
tuning
dependent
★
A2-10
No-load current
0.01 A to A2-03 (AC drive
power ≤ 55 kW)
0.1 A to A2-03 (AC drive
power > 55 kW)
Auto-
tuning
dependent
★
A2-27
Encoder pulses per revolution
1 to 65535
1024
★
A2-28
Encoder type
0: ABZ incremental encoder
2: Resolver
0
★
A2-29
Speed feedback channel selection
0: Local PG card
1: Extension PG card
2: Pulse input (s5)
0
★
A2-30
A/B phase sequence of ABZ
incremental encoder
0: Forward
1: Reserve
0
★
A2-31
Encoder installation angle
0.0 to 359.9
0.0
★
A2-34
Number of pole pairs of resolver
1 to 65535
1
★
A2-36
Encoder wire-break fault detection
time
0.0s: No detection
0.1s to 10.0s
0.0s
★
A2-37
Auto-tuning selection
0 to 3
0
★
A2-38
Speed loop proportional gain 1
1 to 100
30
☆
A2-39
Speed loop integral time 1
0.01s to 10.00s
0.50
☆
A2-40
Switch over frequency 1
0.00 to A2-43
5.00
☆
A2-41
Speed loop proportional gain 2
1 to 100
20
☆
A2-42
Speed loop integral time 2
0.01s to 10.00s
1.00
☆
A2-43
Switch over frequency 2
A2-40 to max. frequency
10.00
☆
A2-44
Vector control slip gain
50% to 200%
100%
☆
A2-45
Speed loop filter time constant
0.000s to 0.100s
0.000s
☆
A2-47
Torque limit source in speed
control
0: A2-48 setting
1: AI1 (Note: J6 jumper)
2: AI2
3: AI3
4: High-speed pulse input (S5)
5: communication given
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
0
☆