Referring the results of other blocks
In Execute All mode, all the set checkers are executed, however, some blocks are not executed in
Automatic Switch mode or User Defined mode.
When referring the result of other blocks, note that it may not work properly depending on the operation
mode used even though it can be set.
Execute All
Mode:
Uses the position adjustment set in other blocks, and refers to the operation and judgement
results of each inspection checker for the numerical calculation or judgement output of other
blocks. However, if other numerical calculation is referred for numerical calculation or if other
judgement output is referred for judgement output, only the expression with a number
smaller than that of the referred expression can be referred.
Automatic
Switch Mode:
Refers to the position adjustment set in other blocks, and the operation and judgement
results of each inspection checker for the numerical calculation or judgement output of other
blocks. However, it does not work properly when referring to a checker of the block that is
not executed by the same start signal.
User-Defined
Mode:
Checkers of other blocks can be set to refer. However, as it is only one block that can be
executed, it does not work properly if the result of another block is referred.
4.4.2 Inspecting in “Execute All” Mode
The “Execute All” is a factory default execution mode.
This mode executes all set checkers. You do not have to be concerned about “Block” in this mode.
Specifying Execution Mode and Number of Blocks
1.
Select "TYPE" > “Type Setting” from the menu bar.
“Type Setting” window is displayed.
2.
Select "Execution Condition".
3.
Select “Execute All” for “Execution
Mode”.
4.
Enter the number of blocks 1 to 10 for
“Number of Blocks”.
4.4.3 Inspecting in “Automatic Switch” Mode
Automatic Switch mode inspects multiple blocks orderly. Firstly block No.0 is executed. The result decides the
next operation; proceed another block, execute the next block, or terminate the inspection. These conditions
can be set in Judgement setting window. (Page 77)
In Automatic Switch mode, only the last block to be executed will be output even when multiple blocks are
inspected.(Example of the output through parallel I/O: Pages 272 and 274) Thus, only when a specific block is
executed last, the result can be output to an external device according to the settings of Judgement or
Numerical calculation of the executed block.
Not only judgement and numerical calculation results but also "Total Judgement" (page 247), "Save Image
Memory" and "Image Output" (page 250) are executed according to the condition of the block executed last.
Example)
When inspecting the front and back face of three types of objects
shown on the right, they are identified their type (A/B/C) and top
or bottom, and then inspected as needed.
Front face
Back face
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......