This function expands or contracts the inspection area or mask area to fit a variable-sized object. The function
detects the part which signifies an object size, such as edges of the object or register marks, and expands or
contracts a checker area based on the coordinates of the part.
Area Size Adjustment is not available for some checkers. In the checkers which can use Area Size Adjustment,
“Area Size Adj.” is displayed in the setting window.
Available:
Line, Binary Window, Gray Window, Binary Edge, Gray Edge, Feature Extraction,
Flaw Detection, Connector (Binary Window), Connector (Gray Window), Smart Edge
(Circle), Smart Edge (Line)
Not available:
Smart Matching, Connector (Gray Edge), Position Adjustment, Area Size
Adjustment
In the Case of Diagonal Inspection Area
When applying Area Size Adjustment on a diagonal inspection area, the function expands or contracts the area
without changing the angle.
Example 1:
Line
Example 2:
Rectangle,
circle, or
polygon
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......