384
O
pe
ra
tio
n a
n
d D
a
ta
O
ut
put
t
hr
ou
gh I
/O
T
e
rm
ina
ls
C
h
ap
te
r 8
8.3.2 Outputting All Results (Output = All)
When the Handshake Function Is Set to “No”
Inspection data are output at intervals of set “Output signal guarantee time (Tp)”. STROBE signal turns on each
time outputting the data.
Receive data with the external device after rising edge of STROBE ON signal and before the next STROBE
signal turns on.
The following is an example of outputting data dividing into three times in Serial mode.
Tf: 400µs (fixed), Tp (1-1000ms): Data output guarantee time (default: 10 ms)
1. As the inspection ends, the first data (OUT signal) is output through I/O interface and turned on
STROBE signal and TACT signal.
Obtain the first result after more than 1 ms of wait time when STROBE signal turns on.
The time from when STROBE signal turns on till when the result output (OUT signal) is determined
varies according to the condition of the connected load or ambient temperature.
2. STROBE signal turns off after the time of Tp passes.
3. As the time of Tp passed from STROBE signal turns off, the second data is output and STROBE
signal and READY signal turn on(*).
Obtain the second result after more than 2 ms of wait time when STROBE signal turns on.
When synchronous output is operated in addition to I/O output, including data output to COM.0 port and
Ethernet port, and inspection image output, READY signal stays OFF until the operation is completed.
4. STROBE signal and TACT signal turn off after the time of Tp passes. Setting "Parallel I/O Output
Reset Condition" to "Reset" resets OUT signal at this timing.
5. I/O result output is complete after the time of "Tp+Tf" passes from TACT signal turns off.
You cannot output the next result while the time of "Tp+Tf" is passing in Parallel mode, and the device is in
the status of waiting for output.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......