418
C
o
nt
rol
w
it
h C
om
m
uni
c
a
tion P
or
t
C
h
ap
te
r 9
Specifications of PLCs
In accordance with specification of PLCs, some of the registers in "Usable range" of "Usable device" listed
below could not be used. Please confirm the specifications of PLC before use.
FP series / FP series (ET-LAN unit) by Panasonic Industrial
Devices SUNX Co., Ltd.
•
Protocol: MEWTOCOL
•
Usable device
Data output/ Type switch
DT
Data output completion notice
Register*
WR
(Usable Range: 0 to 999)
Bit
0-15 (0-F)
•
Sum check: Yes (type: BCC)
Q series / Q series Ethernet unit by Mitsubishi Electric
Corporation
•
Protocol:
-
RS232C interface: “Format 4”, 4C frame compatible for QnA
-
Ethernet interface: 3E frame compatible for QnA
However, communication is only available with Ethernet unit QJ71E71-100.
•
Usable device
Data output/ Type switch
D
Data output completion notice
Register*
M
(Usable Range: 0 to 99999)
Bit
Invalid
•
Make the following setting with PLC.
When using RS-232C Interface
-
Sum check: Yes (type: BCC)
-
Write at RUN time: "Enable"
When using Ethernet interface
-
Communication data code: Binary code communication
-
Initial timing setting: Always wait for OPEN
-
Send frame setting: Ethernet(V2.0)
-
Write at RUN time: "Enable"
A series by Mitsubishi Electric Corporation
•
Protocol: “Format 4”, 1C frame compatible for A
•
Usable device
Data output/ Type switch
D
Data output completion notice
Register*
M
(Usable Range: 0 to 999)
Bit
Invalid
•
Make the following setting with PLC.
-
Sum check: Yes (type: BCC)
-
Modification in RUN mode: Available
FX series by Mitsubishi Electric Corporation
•
CPU: FX1N, Communication adapter: FX1N-232-BD
•
Protocol: Special protocol for FX1N
Register for specifying communication format: Store "0" in D8120. (Reboot the PLC after the setting.)
•
Usable device
Data output/ Type switch
D
Data output completion notice
Register*
M
(Usable Range: 0 to 9999)
Bit
Invalid
•
Sum check: Yes
With PLC, you cannot select to perform sum check. Automatically "Yes" is selected.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......