9.1.2 Ethernet Interface
Ethernet communication is performed with an external device. There are two types of protocol for
communication available, "General Purpose Communication" and PLC Communication" (on Ver.1.50 or later).
Outputting inspection result data, image data, and sending/receiving control commands can be performed. The
product of Ver.1.40 or later can communicate with the designated setting software PVWIN. By using "Image
Receiver for PV", image data can be also output.
Make the settings for Ethernet interface from the following items.
Setting of network
"TOOL" > "General" > "Network"
Page 346
Setting of Ethernet output
"ENVIRONMENT" > "Input/Output" > "General Output"
Page 276
Setting of PLC
communication
"ENVIRONMENT" > "Input/Output" > "General Output” > "PLC
Communication Setting"
Page 424
Setting software “PVWIN”
All the settings except the network setting are set with
PVWIN.
Page 430
Image Output
"ENVIRONMENT" > "Input/Output" > "Image Output"
Page 282
Print Screen
"ENVIRONMENT" > "Input/Output" > "Print Screen"
Page 52
•
Note that incorrect setting of the connection to the existing LAN might cause malfunction in the
devices on the network. Consult your network administrator before connecting.
•
One PV500 cannot be operated by multiple PCs on the network.
•
Depending on the network condition, delay might be caused in the communication. It is advisable to
use I/O interface or RS-232C interface for the operation that requires speedy response such as
inspection trigger input.
Communication Specification of Ethernet
Item
Specifications
Connector
RJ-45
Media
10BASE-T / 100BASE-TX / 1000BASE-T
Protocol
General Purpose Communication: TCP / IP
PLC Communication: UDP / IP
According to the network adapter of your PC, 1000BASE-T communication may not be available.
When you use Ethernet communication with 1000BASE-T, please check the maximum frame size (which is the
data size that can be sent or received in one communication) available in the network environment. In some
cases, the network adapter complying with 1000BASE-T also requires a setting change. For details including
how to set, please contact a manufacturer of network adapters.
About Baud Rate
PV500 automatically adjusts the baud rate according to the speed of the device to communicate. (Auto
negotiation)
You can know the current baud rate by the position and color of LED of Ethernet port that lights when
communicating.
Ethernet Port
LED
Color
Baud Rate
Upper
Yellow
10 megabits
Lower
Green
100 megabits
Orange
1000 megabits
(1 gigabit)
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......