FX-2N series by Mitsubishi Electric Corporation
•
CPU: FX2N, FX3U, FX3UC
Communication adapter: FX2N-232-BD, FX3U-232-BD, FX3U-232-ADP
•
Protocol: Special protocol for FX2N
Register for specifying communication format: Store "0" in D8120. (Reboot the PLC after the setting.)
•
Usable device
Data output/ Type switch
D
Data output completion notice
Register*
M
(Usable Range: 0 to 9999)
Bit
Invalid
•
Sum check: Yes
With PLC, you cannot select to perform sum check. Automatically "Yes" is selected.
C, CV, and CS1 series by OMRON Corporation
•
Protocol: Host link
•
Usable device
Data output/ Type switch
D / DM
Data output completion notice
Register*
CIO / IR
(Usable Range: 0 to 999)
Bit
0-15 (0-F)
•
Make the following setting with PLC.
-
Sum check: Yes
-
Station No.: "0"
•
Communication is not available when PLC is in "Run" mode. Change to "Monitor" mode to communicate.
SLC series by Allen-Bradley
•
Usable device
Data output/ Type switch
N7 (Only integer registers)
Data output completion notice
Register*
N7
(Usable Range: 0 to 254,
only integer registers)
Bit
0-15 (0-F)
•
Make the following setting with PLC.
-
Duplicate Detect: OFF
-
ACK Timeout (*20 ms): 20
-
Control Line: NO HANDSHAKING
-
Error Detect: CRC
-
NAK Retries: 3
-
ENQ Retries: 0
-
Embedded Responses: AUTO DETECT
MICREX-SX (SPH series) by Fuji Electric FA Components &
Systems Co., Ltd.
•
Usable device
Data output/ Type switch
%MW3
Data output completion notice
Register*
%MW3
(Usable Range: 0 to 15360)
Bit
0-15 (0-F)
•
Sum check: Yes (type: BCC, the calculation method developed by Fuji is used.)
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......