Setting Judgement Condition
Perform judgement for the following four conditions respectively. When all the conditions are met, the
judgement result of the checker will be OK.
•
Measurement: Radius, Measurement: Diameter, Measurement: Width
•
Standard deviation (Standard deviation calculated from the result of measurement)
•
Circularity
•
Unused Edge Count
Setting Denoising function
About Denoising function
Measurement values are calculated using the edges
detected by each cell. However, if cells detect
projections, concaves on the surface of the object or
noises existing around it as edges, using this function
enables those edges not to be used for calculating
measurement values. This is "Denoising Function".
Only the edges within a distance or standard deviation
specified based on the radius of a virtual circle are
used for the calculation of measurement values.
Figure 1
Virtual circle
Range of edge
positions used for
calculation
measurement values
About Unused Edge Count
In Denoising function, edges excluded from edges to
be used for calculation and cells which cannot detect
edges are called "unused edge". Edges used for
calculating measurement values are called "used
edge". The number of each edge is displayed in the
left of the screen together with the judgement result of
checker.
Example of edges
excluded by Denoising
function.
1.
Select “Judgement Limits” > "Denoising".
2.
Use either "Distance" or "Std. Devi." for
performing "Denoising".
Distance:
Uses the edges within the distance specified in
"Denoising" based on the radius of a virtual circle for
the calculation of measurement values.
(Area within the dotted line in Figure 1)
Standard Deviation:
Calculates the standard deviation from the radius of a
virtual circle and the edge coordinates detected by
each cell, and uses the edges within the value
calculated by the formula mentioned on the right.
(Area within the dotted line in Figure 1)
"Radius of virtual /- Standard
deviation * Denoising range"
The "Standard deviation" used here is
calculated based on the radius of a virtual circle.
It is different from the "Standard Deviation"
displayed on the screen (that is a criterion for
judgement).
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......