139
Se
tt
ing I
n
s
p
e
c
tio
n C
on
d
it
ions
C
h
ap
te
r 4
INDE
X
In the case of Area Shape = “Plane”
1
. Set a start point and an end point.
Set a start point (STX, STY) and an end point
(EDX, EDY). PV scans from the start point to
the end point.
If the scan direction is set to
“Horizontal/Vertical”, PV scans in both
directions.
2
. Set the size of a cell which is a rectangle
calculating the average brightness.
Scan direction: Horizontal
Scan direction: Vertical
3
. Set the number of cells.
Settable number of cells:
- Number of cells X = 3 - 256
- Number of cells Y = 3 - 256
Set the number of cells in order to inspect the
object thoroughly from the start point to the end
point in both directions of X and Y, and not to
overlap cells each other as the figure shown on
the right. If the cells overlap each other, the
checker repeatedly scans the parts where the
cells are overlapping, resulting in increasing
inspection time.
Changed area size by Area Size Adjustment
function does not change the number of cells.
Specify the number of cells in order to inspect
thoroughly even if an area size will become
larger.
The lower figure is an example of occurrence of area
that cannot be inspected due to lack of cells.
X
(Left/right key of the
keypad).
Y
(Up/down key of the
keypad).
ST
X coordinate of the
start point
Y coordinate of the
start point
ED
X coordinate of the
end point
Y coordinate of the
end point
W
Width-X of cell
Width-Y of cell
N
Number of cells in X
Number of cells Y
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......