118
Se
tt
ing I
n
s
p
e
c
tio
n C
on
d
it
ions
C
h
ap
te
r 4
Selecting Feature Data to Measure
Select feature quantity data to measure on a detected object. Setting unnecessary items to “No” decreases the
inspection time.
Selectable feature data types are Perimeter, Projection Width/Height and Principal Axis Angle.
1.
Select "Search Method".
2.
Set whether or not to detect Perimeter,
Projection Width/Height and Principal Axis
Angle.
Yes
(default): Measures the selected item.
No
: Does not measure the selected item.
When setting labeling to "No", Perimeter and Projection Width/Height cannot be detected.
When setting Principal Axis Angle to “No”, Projection Width/Height cannot be detected.
Changing Other Search Methods
(Labeling/Boundary/Fill Holes)
1.
Select "Search Method".
2.
Change the setting of Labeling, Boundary, or Fill Holes as necessary.
Extracting Each Data of Multiple Objects (Labeling)
This is a function to detect each Feature data when multiple objects exist within the area.
Yes (default):
Measures feature quantity of each object.
No:
Feature quantity of each object is not measured and only total area, coordinate of the
gravity center, and principal axis angle are output.
Decides Whether or not to Detect an Object on the Boundary
of an Area (Boundary)
Yes (default):
Detects an object on the area frame.
No:
Ignores an object on the area frame.
You can set Boundary to “Yes” only when Labeling is set to “Yes”.
Selecting Whether or not to Fill inside an Object with the
Target Color (Fill Holes)
If there is a part with different color from the
target color inside an object, measurement
of coordinate of gravity center or principal
axis angle is interfered. To prevent this,
processes to fill inside the object with the
target color.
Yes (default):
Executes Fill Holes.
No:
Does not execute Fill Holes.
Fill Holes is available when Labeling is set to “Yes”.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......