Registering Data in Data R/W Sheet
1.
Select a sheet number of Data R/W to
register data in Data R/W setting window.
2.
Select a cell to register data.
The item selecting window is displayed.
-
For the information of settable items,
refer to page 296.
-
When the settable items in the list are
displayed in gray (when the color setting
is the default), it shows that those
parameters are not available or the
results do not exist.
For example, the scan pitch in the
parameters of gray edge is only
available when the shape of the area is
"Plane". When the shape is "Line",
"Scan Pitch" is displayed in gray.
3.
Select data to register.
Depending on data type, details including checker number or parameter are needed to be selected.
Follow the window display.
For some checkers, the list of result types is displayed on multiple pages. Tilt the ENTER key left or light
to change the page.
The description field shows the detail of registered data after registration.
Now you completed registering data. Set the following two items as necessary.
-
Character alignment: Display position of characters in a cell
-
Overwrite permission: Setting to permit overwriting data in RUN menu
•
Data with value after decimal point is displayed
3-digit after the point. The display digits after
decimal point can be changed from the pop-up
menu displayed by pressing the FUNC key.
•
In Connector (Binary Window), Connector (Gray
Window), Connector (Gray Edge), you can register
some types of data into Data R/W sheet from the
setting windows. Refer to the description of each
checker for details.
Character Alignment and Overwrite Permission
1.
Press the FUNC key and select “Alignment” from
the pop-up menu.
Select from Right (default), Center, and Left.
2.
Select "Overwrite" from the same menu.
Every time you select “Overwrite”, permission status
switches between on (checked) and off (unchecked). In
the default setting, overwriting is permitted.
This item is selectable only when you select the registered data that can be overwritten such as
parameters of checkers.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......