396
C
o
nt
rol
w
it
h C
om
m
uni
c
a
tion P
or
t
C
h
ap
te
r 9
9.2 Communication Command
9.2.1 List of Commands
The commands described in this chapter are the common commands for the ports to control PV500 through
RS-232C interface and Ethernet interface.
Port number of Ethernet interface to send/ receive commands for PV500 is “8604”.
List of Commands
The commands and the modes permitting the commands are listed below.
Command Permission
RUN Menu
SETUP Menu Parallel
Processing
Continuous
Inspection
Command RUN
STOP RUN
STOP
Inspection start
Common Trigger
%S
Yes
Yes
Yes
Yes
Individual
Trigger
%S
Yes
Yes
Yes
Stop repeating inspection
%S
Yes
Yes
Yes
Yes
Stop Detect trigger execution
%S
Yes
Yes
Yes
Start reinspection (to inspect on the
current memory image without
capturing a new image)
%R
Yes
Yes
Switch product type
%X
Yes
Yes
Yes
Yes
Save the
setting data
Storage space in
PV500
%MW
Yes
Yes
Yes
Yes
SD memory card
%CW
Yes
Yes
Yes
Yes
Read the
setting data
Storage space in
PV500
%MR
Yes
Yes
Yes
Yes
SD memory card
%CR
Yes
Yes
Yes
Yes
Abort save/read setting data
(Cancel)
%CD
Yes
Yes
Yes
Yes
Image
memory
Save (in a SD card)
%SS
Yes
Yes
Yes
Yes
Clear
%SR
Yes
Yes
Yes
Yes
Print screen
%PS
Yes
Yes
Yes
Yes
Reset statistics
%Q
Yes
Yes
Yes
Yes
Switch between RUN/STOP
%RM
Yes
Yes
Yes
Yes*
1
Yes
Yes
Reset error signal
%E
Yes
Yes
Yes
Yes
Yes
Yes
Key emulating
%K
Yes
Yes
Yes
Yes
Yes
Yes
Keypad
Operation
Invalid/Valid
%BS
Yes
Yes
Yes
Yes
Confirm Status
%BC
Yes
Yes
Yes
Yes
Yes
Yes
Cancel Inspection/ Process
%CC
Yes
Yes
Yes
Yes
Yes
Yes
Switch layout
%I
Yes
Yes
Yes
Set a template
%A
Yes
Parameter
Read
%PR
Yes
*2
Yes
*2
Yes
Yes
Read pairs
(Maximum/minimum
values)
%PRP
Yes
Yes
Yes
Yes
Change
%PW
Yes
Yes
Yes
Change pairs
(Maximum/minimum
values)
%PWP
Yes
Yes
Yes
*1 This cannot be executed when you select “TOOL” > "General", "Setting Help", or "Update".
*2 Only operation status (parameter: SYS_RUN) and screen status (parameter: SYS_EDIT) can be read.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......