407
C
o
nt
rol
w
it
h C
om
m
uni
c
a
tion P
or
t
C
h
ap
te
r 9
INDE
X
Setting Invalid/Valid of Keypad operation
This is a command for prohibiting/permitting keypad operation in RUN MENU.
When keypad operation has been set to "Invalid", the keypad cannot be used. A message "Keypad is invalid" is
shown in the key guide space on the window. Even when setting to "Invalid", key emulate commands can be
received.
Send
% B S ?
BCC
CR
? = 0-1 (0 = Valid. 1 = Invalid)
Receive
% B S $ BCC(10) CR
Error
(ERROR 1 signal =
ON)
% B S ! Error code (3-digit)
BCC
CR
Error Code
270
Not available because SETUP MENU is displayed.
271
Other number than 0.1 and 1 is specified.
Reading Keypad Operation Status
Send
% B C
BCC
CR
BCC = 24 or **
Receive
% B C $ ?
BCC
CR
? = 0-1 (0 = Valid. 1 = Invalid)
Canceling Inspection/ Processing (Cancel specific
operation)
Cancels the following active operations, and restores into the previous status before the operation.
•
Cancellation of the operation of a serial command which has been received
•
Abort of the status waiting for Individual trigger input
•
Abort of output in the status waiting for result output after an inspection is complete
•
Abort of image saving from Image Memory to a SD memory card
•
Cancellation of template re-registration
Send
% C C
BCC
CR
BCC = 25 or **
Receive
% C C $
BCC(01) CR
Layout Switch
Send
% I
? ?
BCC
CR
?? = 00 – 31 (Layout No.)
Receive
% I
$
BCC(48)
CR
Error
(ERROR 1 signal = ON)
% I
!
Error code (3-digit)
BCC
CR
Error code
200
Operation is stopped
245
• Although PV500 is operating (RUN), displaying SETUP menu cannot
switch layout.
246
• Other number than 00-31 is specified for layout number.
• No layout has been registered in the specified layout number.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......