PanaVoice Courier Installation Manual 104
INTERNAL DELIVERY START TIME – DEFAULT: 00:00
When to start delivering messages. Use military format. (00:01 through 23:59) For
example, 2:00 a.m. is 0200, and 11:30 p.m. is 2330.
INTERNAL DELIVERY STOP TIME – DEFAULT: 23:59
When to stop delivering messages. Use military format. (00:01 through 23:59) For
example, 2:00 a.m. is 0200, and 11:30 p.m. is 2330.
Select Apply to apply any item without leaving this screen. Select Cancel to leave this
screen without saving any changes. Select OK to apply all changes and leave this
screen.
LAMP ON PROTOCOL – DEFAULT: (BLANK)
This field defines the DTMF sequence used to turn on a message-waiting light at the
extension, when a new message is to be delivered. (e.g.: *4X would be used for DBS
824, 40 72 and 96 systems)
Note: The field under Add Mailboxes which determines the message notification method must be
set to Light in order for these Protocols to work. These Lamp Protocol fields are not relevant
when using API integration.
LAMP OFF PROTOCOL – DEFAULT: (BLANK)
This field defines the DTMF sequence used to turn off a message-waiting light. (e.g.:
*5X would be used for DBS 824,40 72 and 96 systems.)
Note: The field under Add Mailboxes, which determines the message notification method, must
be set to Light in order for these Protocols to work. These Lamp Protocol fields are not relevant
when using API integration.
Summary of Contents for PanaVoice Courier
Page 15: ...PanaVoice Courier Installation Manual 14 TW O PO RT COURIER SC H EM AT IC...
Page 16: ...PanaVoice Courier Installation Manual 15 FO U R PO R T COURIER PLUS SCH EM AT I C...
Page 17: ...PanaVoice Courier Installation Manual 16 FO U R PO R T COURIER UMS SC H EM AT I C...
Page 80: ...PanaVoice Courier Installation Manual 79 COURIER QUICK REFERNCE CARD...