61
4.
Connect the three wires to the terminals.
The signs of “L (black)”, “N (white)” and “PE (GND) (yellow/green)”
show in the cables. Connect each cable to the appropriate terminal.
Screw size: M4
Tightening torque: 1.8N·m
ワㄐㄕㄊㄆ
• For the AC power supply cable, use the specified optional AC power
cable or a cable with the enough rating capacity to fulfil the power
voltage specification of this product.
• Use a cable compliant with the regulations and standards in the country
or region where it is used.
5.
Attach the resin cover to the terminal.
6.
Attach the power supply cover.
Screw size: M3
Tightening torque: 0.5N·m
7.
Fix the AC power cable with the clamp.
Screw size: M4 screw
Tightening torque: 1.0N·m
8.
Make sure that the cables and connectors other than the power supply are connected and then connect the AC power
cable to the AC power supply.
Power voltage: 90V to 132V or 180V to 264V AC (including ±10% voltage fluctuations)
ワㄐㄕㄊㄆ
• The earth terminal of the AC power cable must be permanently grounded.
• Set each connecting cable away from the device that generates high voltage, power line, and large switching surge as
far as possible. If there may be any noise effect on the power supply, use the noise cut-off transformer.
/
1
3(
L N
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......