3-4-4 Remote mode settings
To control the laser marker externally via I/O or communication commands, set the operation mode to the remote mode
with one of the following methods.
Select the method to switch to the remote mode on the system settings screen of Laser Marker NAVI smart. Refer to “3-4-3
General settings before external control” (P.86).
Remote mode switching by Laser Marker NAVI smart
Select “Operation” in the ribbon.
In the dialog, select “Remote ON” and select “Yes” to confirm.
Startup the laser marker in the remote mode (Laser Marker NAVI smart can switch the remote mode)
When you turn ON the key switch of the laser marker, the system starts in the remote mode. Use the operation tool of
Laser Marker NAVI smart for releasing and resetting the remote mode.
ンㄆㄇㄆㄓㄆㄏㄆ
• If you want to start up the laser marker in the remote mode, you need to configure the settings on the system settings
screen of Laser Marker NAVI smart in advance.
• If you have configured the laser marker to start up in the remote mode, you cannot switch the remote mode from I/O.
Remote mode switching using I/O
Turn ON REMOTE IN (X4) of the I/O terminal block on the
controller.
ンㄆㄇㄆㄓㄆㄏㄆ
• To enable switching to the remote mode by REMOTE IN (X4) on the I/O terminal block, you need to configure the
settings on the system settings screen of Laser Marker NAVI smart in advance.
• If you have configured the remote mode switching method to the I/O terminal block, you cannot switch the remote mode
from the Laser Marker NAVI smart screen.
WARNING
• If the laser marker is set to enter the remote mode at startup or by I/O control,
construct a manual resetting system to re-pump the laser when the laser
pumping is turned to off due to an emergency stop or an interlock.
Remote mode ON
“Operation” tool
Remote mode OFF
REMOTE IN
X1
X2
X3
X4
X5
X6
X7
Y1
Y2
Y3
Y4
Y5
Y6
Y7
PLC, etc.
OUTPUT
I/O terminal block
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......