189
9.
Click “Stop” to stop laser radiation.
The laser radiation for measurement will automatically
stop after about one minute even without clicking “Stop”.
10.
Check the measurement results of the power meter. If
the power decays lower than the default setting, correct
the laser power setting value in the “System settings”
screen – “System offset”.
Setting range of laser power correction: 50 to 200 [%]
ンㄆㄇㄆㄓㄆㄏㄆ
• Laser power correction refers to the function to correct not the maximum laser power [W] value but the laser power
setting value.
ワㄐㄕㄊㄆ
• If the power decays more than 20%, compared to the default setting, the laser oscillator needs maintenance. Contact our
sales office or representatives.