123
4-6-5 On-the-fly marking: Single trigger
ON (Open)
OFF (Close)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T3
T2
T2
T4
T5
T5
T4
T3
T1
SHUTTER OPEN OUT
(No.39)
READY OUT (Y5)
TRIGGER IN (X5)
PROCESSING OUT (Y10)
LASING OUT (No.40)
PROCESSING END OUT
(Y11)
Item
Time
Remarks
T1
―
Time for marking data creation. It varies depending on the quantity of the setting data.
T2
2ms or more
Keep the ON status for 2ms or more.
T3
―
Time from when TRIGGER IN (X5) is turned on till when the workpiece comes to the
preset marking position.
T4
2 to 510ms
This is the output to notify that the marking trigger processing completed normally. This is
One-shot output. Set the output time on System settings screen. There is a small margin of
error for the setting value.
T5
―
Time for marking data creation.
When the next marking data is not ready during the marking operation, this is the rest time
for data creation.
When the next marking data is ready during the marking operation, this takes less than
1ms.
ンㄆㄇㄆㄓㄆㄏㄆ
• If the counter is reset during on-the-fly marking operation, READY OUT (Y5) turns off momentary and there is a case
that the next marking could not be executed due to Warning E751.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......