188
3.
Establish an online connection between your PC and the laser marking system. Go to the “Maintenance” screen.
4.
Click “Laser pumping” in the ribbon to turn on the laser pumping.
5.
Click “Laser radiation for measurement” in the ribbon.
6.
Click “Guide laser ON” to confirm the setting position of
the power meter detector. Place the detector so that the
cross indication is on the center of the detector.
7.
Click “Guide laser OFF”.
8.
Enter the laser power and other laser settings, then click
“Laser radiation”.
Click “Yes” in the laser radiation confirmation dialog to
irradiate the laser.
ンㄆㄇㄆㄓㄆㄏㄆ
• Use the guide laser to confirm the setting position of the power meter
detector. Place the detector so that the cross indication is on the center of
the detector.
• For stable measurement results, it is recommended to obtain the average
output value by measuring the output after about 30 seconds from the start
of laser radiation for 10 to 30 seconds.
• The settings of laser radiation for measurement are common in all files.
WARNING
• Be sure to wear protective goggles.
• During the radiation, the laser energy is concentrated to one point. Use due
caution with long period radiation, it may cause a fire or damage to the object.
ON status
“Laser pumping” tool
OFF status
“Laser radiation for
measurement” tool
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......