184
6.
Install the fans in the direction so that the air flow arrow on the fan points to the laser marker and the fan cable is on
the bottom side.
Put the fan guard on the fan and attach the nuts (M4, opposite side 7mm) to the screws coming out of the controller
side.
Airflow direction
Laser marker
ワㄐㄕㄊㄆ
• Install the controller fans in the direction so that the air flow matches the intake direction.
Fan installed in the wrong way causes the flow to go in the wrong way, which may failure of the product.
• Be careful not to let the cable get caught while installing.
7.
Fasten the screws (4 nuts for 1 fan) from the top of the fan guard to secure the fan to the controller.
Nut size: M4
Tightening torque: 1.0 N·m
8.
Connect the connector for the fan. (One connector for one fan)
Connector
ME-LPRH-SM-3